期刊文献+

纯电动汽车充电机系统稳定性研究 被引量:12

System stability of battery charger for battery electric vehicle
在线阅读 下载PDF
导出
摘要 一般纯电动汽车充电机的控制系统基于额定输入电压、充电电流等条件设计,忽略了工作条件变化和元器件寄生参数对系统稳定性的影响。为了保证在充电过程中充电机能够稳定工作和进一步了解充电机系统稳定性的机理,建立基于全桥拓扑结构的纯电动汽车充电机的平均线性小信号模型。依据该线性小信号模型推导出表征充电机特性的关键传递函数。通过MATLAB仿真,研究纯电动汽车充电机在拓扑结构和主要参数确定的情况下,影响其控制环路特性的因素如输入电压、充电电流、输出滤波器等效串联电阻与表征控制环路特性的参数如穿越频率和相位裕度之间的关系,并用实验证明了理论分析的正确性。 The battery charger control system for battery electric vehicle is designed according to the conditions of rated input voltage and charging current.The influences of working condition change and components’ parasitic parameters on the system stability are always ignored.In order to guarantee the stable work of battery charger under all conditions and further understand the mechanism of system stability,its average linear small-signal model is established based on the full-bridge topological structure and the key transfer function is deduced to represent its characteristics.MATLAB simulation is carried out to study the relation between the influencing factors of control loop characteristics when the topology and parameters of charger are fixed,such as the input voltage,charging current and equivalent series resistance of output filter,and the representing parameters of control loop characteristics,such as the crossover frequency and phase margin.Experimental results show the correctness of theoretical analysis.
作者 李晶 姜久春
出处 《电力自动化设备》 EI CSCD 北大核心 2012年第9期13-17,共5页 Electric Power Automation Equipment
基金 国家高技术研究发展计划(863计划)(2011AA05A108)~~
关键词 电动汽车 充电机 系统稳定性 环路增益 穿越频率 electric vehicles battery charger system stability loop gain crossover frequency
  • 相关文献

参考文献16

二级参考文献67

  • 1伍小杰,罗悦华,乔树通.三相电压型PWM整流器控制技术综述[J].电工技术学报,2005,20(12):7-12. 被引量:115
  • 2郎永强,徐殿国,HADIANAMREI S R,马洪飞.三相电压型PWM整流器的一种改进前馈控制策略[J].电机与控制学报,2006,10(2):160-163. 被引量:49
  • 3步宏飞,肖岚.加双CDD无源无损缓冲电路的推挽正激变换器[J].电力电子技术,2006,40(3):50-52. 被引量:9
  • 4朱成花,严仰光.一种改进的阻抗比判据[J].南京航空航天大学学报,2006,38(3):315-320. 被引量:14
  • 5魏金强,全书海,陈启宏.燃料电池发动机风量模糊PID控制器的设计[J].武汉理工大学学报(信息与管理工程版),2007,29(1):22-26. 被引量:3
  • 6KOMURCUGIL H,KUKRER O. A novel current-control method for three- phase PWM AC/DC voltage- source convertors [J]. IEEE Trans on Industrial Electronics, 1999,46 ( 3 ) : 544 - 553.
  • 7DIXON J W,OOI B T. Indirect control of a unity- power factor sinusoidal current boost type three- phase rectifier [J]. IEEE Trans on Industrial Electronics, 1998,35 (4) : 508 - 515.
  • 8KARRARI M,ROSEHART W,MALIK O P. Comprehensive control strategy for a variable speed cage machine wind generation unit [J]. IEEE Trans on Energy Conversion,2005,20(2):415-423.
  • 9LISERRE M,TEODORESCU R,BLAABJERG F. Stability of photovoltaic and wind turbine grid- connected inverters for a large set of grid impedance values[J]. IEEE Trans on Power Electronics ,2006,21 ( 1 ) :263 - 272.
  • 10LIN B R,HOU Y L. Single- phase integrated power quality compensator based on capacitor-clamped configuration[J]. IEEE Trans on Industrial Electronics ,2002,49( 1 ) : 173 - 185.

共引文献98

同被引文献111

引证文献12

二级引证文献80