期刊文献+

老年人64层螺旋CT冠状动脉成像的临床技术特点及应用 被引量:10

Techniques and clinical application of 64-slice spiral CT coronary angiography in aged people
暂未订购
导出
摘要 目的探讨老年人64层螺旋CT冠状动脉成像的技术特点及临床应用价值。方法对257例老年冠状动脉疾病患者行64层螺旋CT冠状动脉造影检查,针对老年患者的特点选用适合的检查技术,并评价所获得的图像质量;将患者按照年龄分组,分为65~74岁、75~84岁、≥85岁三组,分别统计各组CT冠状动脉成像的成功率并总结成像技术特点。结果 257例老年患者的2150段冠脉血管中,2041段冠状动脉血管(94.93%)图像质量可以满足影像学诊断。经统计学方法处理,表明在不同年龄组的老年患者中,冠状动脉成像显示成功率无显著性差异。结论 64层螺旋CT对老年人冠状动脉成像有很好的显示成功率,可作为老年人冠状动脉病变的一种有效筛选方法;在对老年人行CT冠状动脉成像检查时,根据老年人的特点适当的运用成像技术会获得良好的效果。 Objective To investigate the techniques and evaluate the clinical application of 64-slice CT coronary angiogra- phy in aged people. Methods 257 patients with coronary artery disease (CAD) were enrolled in this study, and the CT image quality was graded as follows:A, excellent; B, good; C, poor; D, very poor. The image quality of A and B were sufficient in diagnosis. Estimate the imaging effect in different age groups (group A.. 65 to 74 years old; group B.. 75 to 84 years old; group C: over 85 years old) and summarize the point of techniques. Estimate the value of the 64-slice CT coro nary angiography in the diagnosis of the coronary disease. Results 94.93% of the coronary segments were sufficient for diagnosis in the 257 patients. The rate of success for coronary imaging was not related with age in statistics. Conclusion Coronary imaging with 64-slice CT showed a high sufficiency for diagnosis in aged people. According the features of aged people, using the appropriate techniques can be helpful for coronary imaging.
出处 《医学影像学杂志》 2012年第8期1294-1297,共4页 Journal of Medical Imaging
关键词 老年人 体层摄影术 X线计算机 冠状动脉成像 Aged people Tomography, X-ray computed Coronary artery angiography
  • 相关文献

参考文献8

二级参考文献38

  • 1潘爱珍,甘毅,陈涛,郑建忠,黄慧玲.16层CT冠状动脉成像质量探讨[J].中国CT和MRI杂志,2004,2(3):27-29. 被引量:43
  • 2肖喜刚,韩雪,王雪红,孙宏亮,王鸿振,牛洪涛.多层螺旋CT冠状动脉成像在冠心病中的临床应用[J].中华放射学杂志,2004,38(9):957-961. 被引量:66
  • 3王锡明,武乐斌,李振家,柳澄,陈海松.64层螺旋CT在冠状动脉造影中的应用[J].中华放射学杂志,2005,39(11):1201-1204. 被引量:153
  • 4廖友芝,刘少欣,高焕新.MRI增强扫描患者不同检查阶段的心理特点及其护理[J].护理学杂志,2006,21(1):70-71. 被引量:31
  • 5Oevrehus KA, Boettcher M,Larsen HM,et al. Impact of procedure volume and operator experience on the diagnostic accuracy of computer tomographic coronary angiography. J Am Coll Cardiol,2009,53:A264.
  • 6Ko SM,Kim NR,Kim DH,et al.Assessment of image quality and radiation dose in prospective ECG-triggered coronary CT angiography compared with retrospective ECG-gated coronary CT angiography. Int J Cardiovasc Imaging,2010,26 Seppl 1:93-101.
  • 7Pflederer T,Jakstat J,Marwan M,et al.Radiation exposure and image quality in staged low-dose protocols for coronary dual-source CT angiography:a randomized comparisor. Eur Radiol,2010,20:1197-1206.
  • 8Srichai MB,Hecht EM,Kim D,et al. Dual-source computed tomography angiography image quality in patients with fast heart rates.J Cardiovasc Comput Tomogr,2009,3:300-309.
  • 9Alkadhi H,Stolzmann P,Scheffel H,et al.Radiation dose of cardiac dual-source CT:the effect of tailoring the protocol to patient-specific parameters.Eur J Radiol,2008,68:385-391.
  • 10StolzmannP,Scheffel H,Schertler T,et al. Radiation dose estimates in dual-suource computed tomography coronary angiography.Eur Radiol,2008,18:592-599.

共引文献189