高效液相色谱法快速测定小麦粉中过氧化苯甲酰 被引量:6

Rapid Determination of Benzoyl Peroxide in Wheat Flour by High Performance Liquid Chromatography
在线阅读 下载PDF
导出
摘要 目的:用高效液相色谱准确、快速测定小麦粉中过氧化苯甲酰。方法:小麦粉直接以水溶解,经振荡及超声提取,滤膜过滤后上高效液相色谱进行测定。结果:苯甲酸在0.2μg/ml~100μg/ml范围内呈良好线性,检出限为0.3mg/kg。平均回收率在94.1%~99.0%范围内。相对标准偏差小于2%。经检验,本法对CNCA能力验证剩余样品的检测结果与CNCA公布结果基本一致。结论:本法简单快捷,结果准确,重现性好,适用于小麦粉中过氧化苯甲酰的测定。 Objective: To determination the benzoyl peroxide in wheat flour in a rapid and accurate way. Methods: After being extracted by water, shaking extraction, ultrasonic vibration extraction and membrane filtration ,wheat flour were analyzed by HPLC. Results: The benzoyl peroxide was shown to be linear in the range from 0.2 μ g/ml to 100 μ g/ml, the limit of detection was 0.3mg/kg.The recovery of the method was between 94.1% and 99.0%. The precisions (RSD) were less than 2%. There was no statistical difference between the sample results of this method and the results reported by CNCA. Conclusion: The method is simple, sensitive, accurate, specific and reproducible in the determination of benzoyl peroxide in wheat flour.
出处 《福建分析测试》 CAS 2012年第4期16-19,共4页 Fujian Analysis & Testing
关键词 高效液相色谱 过氧化苯甲酰 快速测定 high performance liquid chromatography benzoyl peroxide Determination