综合性放射防护措施在介入治疗防护中的应用 被引量:19

The clinical application of comprehensive radiation protection measures in interventional radiology
暂未订购
导出
摘要 目的探讨综合性放射防护措施在介入治疗防护中的应用价值。方法在84例介入手术治疗中联合应用床下铅橡胶帘、铅玻璃防护屏、铅防护服、铅围脖、铅眼镜及距离等对介入操作人员进行综合性防护。利用FJ-2000个人剂量仪监测X射线辐射剂量,并对相关数据进行统计分析。结果床下铅橡胶帘防护效率为93.4%;铅玻璃防护屏防护效率为93.5%;铅防护服防护效率为88.4%这些放射防护器材前后X线辐射剂量差异均具有统计学意义(P<0.01)。距球管1 m处X线衰减量为58.6%,距球管3 m处的X线衰减量为86.4%。1 m与2 m之间,2 m与3 m之间的辐射剂量差异均具有统计学意义(P<0.01)。结论综合性防护措施在介入操作中可有效降低X射线辐射、减少对介入操作人员身体危害。 Objective To discuss the clinical application of comprehensive radiation protection measures in interventional radiology. Methods By a combination use of bed lead rubber curtain, moveable lead glass shield, protective clothing, lead collar, lead glasses and exposure distance, interventional procedures were performed in 84 patients. The X-ray radiation dose of the operators was monitored by FJ- 2000. The results were statistically analyzed. Results The radiation doses estimated before and after the use of lead rubber curtains, lead glass shield, and lead protective clothing were (67.9l ± 73.45)μSv vs. (4.47 ± 10.37)μSv, (56.46 ± 41.23)μSv vs. (3.68 ± 6.46)μSv and (5.2 ± 8.81)μSv vs. (0.61 ± 1.36)μSv, respectively, and the protective efficiency were 93.4% , 93.5% and 88.4% , respectively. The differences were statistically significant (P 〈 0.01). The radiation doses at the spots 1 m, 2 m, and 3 m from the tube were (1.91 ± 2.12)μSv, (0.79 ± 1.92)lxSv and (0.26 ± 1.01)txSv, respectively. The attenuations of radiation dose at the spots 1 m and 3 m from the tube were 58.6% and 86.4%, respectively. The differences in radiation dose between the distance 1 m and 2 m, as well as between the distance 2 m and 3 m, were statistically significant (P 〈 0.01). Conclusion The use of comprehensive protective measures can effectively reduce the radiation dose to the operators attending the interventional procedures. (J Intervent Radiol, 2012, 21:514-515)
出处 《介入放射学杂志》 CSCD 北大核心 2012年第6期514-515,共2页 Journal of Interventional Radiology
关键词 辐射 防护 介入放射学 radiation protection interventional radiology
  • 相关文献

参考文献6

二级参考文献17

  • 1成君方,张翼,张丹枫,傅爱玲.介入放射学综合防护措施的研究[J].生物医学工程与临床,2001,5(2):74-77. 被引量:9
  • 2Valentin J. Avoidance of radiation injuries from medical interven- tinal procedure[J]. Ann ICRP, 2000, 30:7 - 67.
  • 3Miller DL, Balter S, Cole PE, et al. Radiation doses in interventional radiology procedures: the RAD-IR study pare I: overall measures of dose [J]. J Vasc Inter Radiol, 2003, 14: 711 - 727.
  • 4UNSCEAR. Sources and Effects of loniziong Radiation [ M ]. New York: UN, 2000.
  • 5白玫,刘彬,郑钧正.心脏介入患者受照剂量研究[J].介入放射学杂志,2007,16(4):222-225. 被引量:14
  • 6Pron G,Bennett J,Common A,et al.Technical results and effects of operator experience on uterine artery embolization for fibroids:the ontario uterine fibroid embolization trial[J].JVIR,2003,14:545-554.
  • 7Miller DL,Balter S,Cole PE,et al.Radiation doses in interventional radiology procedures:The RAD-IR study.Part I:overall measures of dose[J].JVIR,2003,14:711-728.
  • 8Nikolic B,Abbara S,Levy E,et al.Influence of radiographic technique and equipment on absorbed ovarian dose associated with uterine artery embolization[J].JVIR,2000,11:1173 -1178.
  • 9Nikolic B,Spies JB,Campbell L,et al.Uterine artery embolization:reduced radiation with refined technique[J],2001,JVIR,12:39-44.
  • 10Nikolic B,Spies JB,Lundsten MJ,et al.Patient radiation dose associated with uterine artery embolization[J].Radiology,2000,214:121-125.

共引文献46

同被引文献148

引证文献19

二级引证文献77

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部