摘要
在自动喷水灭火系统设计中 ,系统配水管网管径的设计是十分重要的 ,它不仅关系到整个系统的造价 ,更关系到系统消防的安全性 .通过算例分析 ,说明了管径设计参数——设计流速不大于 3m/ s,设计比较安全、经济、合理 .
In designing an automatic sprinkling fire extinguisher system, it is very important to design the pipe diameters in a pipeline network of water supply system, which is related not only to the costs of the whole system but also to the safety of fire extinguisher system. By analyzing examples, it is demonstrated that the design is safe, economical and reasonable when the design parameter of pipe diameter fluid velocity designed is less than 3 m/s
出处
《华东交通大学学报》
2000年第1期7-11,共5页
Journal of East China Jiaotong University
关键词
自动喷水
管径
流速
作用面积
灭火系统
automatic sprinkling
diameter of pipes
velocity of fluid
acting area