期刊文献+

高置信度的显著误差综合检测法 被引量:7

A Compound Test with High Confidence Level for Gross Error Detection
在线阅读 下载PDF
导出
摘要 实际生产过程要求显著误差检测有相当高的准确性 ,即要求“虚警”和“漏报”的概率都很低。但目前使用的各种方法往往很难同时满足这两个要求。本文提出了一类高置信度的检测法 ,使得“虚警”和“漏报” A number of gross error detection techniques are widely applied in different chemical processes.However,their performances have not always been so satisfactory.For example,the low probability of type I error always causes the high are of type Ⅱ error.Here,a compound test with high confidence level(HCL test)is presented in this paper,which has a low percentage of both two types of errors.Moreover,a practical example based on real process data is provided and a comparison with other tests proves that the new method is quite effective.
作者 王希若 荣冈
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2000年第2期196-199,共4页 Chinese Journal of Scientific Instrument
基金 国家863CIMS主题基础研究课题
关键词 显著误差检测 数据校正 高置信度 虚警 漏报 Gross error detection Data reconciliation
  • 相关文献

参考文献9

二级参考文献70

共引文献365

同被引文献61

引证文献7

二级引证文献45