摘要
为提高机组的运行经济性 ,衡水发电厂对# 13 0 0MW机组进行了单阀定压、顺序阀定压、定—滑—定、全滑压 4种运行方式不同负荷下的对比试验 ,通过对试验数据的比较 ,确定出机组的最佳运行方式。
To promote the economic operation, comparison tests are performed in Hengshui Power Plant in four different operation conditions: onevalve fixed pressure, sequence valving fixed pressure, fixedslidefixed pressure, and whole slide pressure. Through the comparison of data from these different tests, the optimal operation mode of the unit is identified.
出处
《河北电力技术》
2000年第1期12-14,共3页
Hebei Electric Power