期刊文献+

自动喷水灭火系统设计流量压力计算比较分析 被引量:1

Comparative analysis of design flow and pressure calculation of sprinkler systems
在线阅读 下载PDF
导出
摘要 通过对同一个自动喷水灭火系统,分别采用特性系数+当量长度法、特性系数+百分数法和估算法进行设计流量、压力计算、比较分析,结果表明:采用特性系数+当量长度法计算的结果最接近实际工况;特性系数+百分数法的计算结果略小于特性系数+当量长度法;估算法计算值最小,不能满足设计规范的要求,提出对于严重危险和仓库危险级场所,必须采用特性系数+当量长度法进行水力计算,对于轻中危险级场所,建议采用特性系数+百分数法计算。 The article uses characteristic coefficients+equivalent length method,characteristic coefficients+percentage method and estimation method to calculate the design flow and pressure in the same automatic sprinkler system respectively.The results show:the result calculated by the characteristic coefficients+equivalent length method is closest to the actual working condition;the result by characteristic coefficients+percentage method of calculation is slightly smaller than that by characteristic coefficients+equivalent length method;the result by estimation method is smallest and can not meet the design requirements.The characteristic coefficients+equivalent length method must be used for serious dangerous and warehouse risk grade places.The characteristic coefficients+percentage method are recommended at light or intermediate dangerous places.
出处 《山东建筑大学学报》 2012年第1期119-121,共3页 Journal of Shandong Jianzhu University
关键词 自动喷水灭火系统 特性系数 流量 压力 喷水强度 sprinkler systems characteristic coefficients flow pressure spray intensity
  • 相关文献

参考文献4

二级参考文献5

  • 1NFPA 13-2010 Standard for the installation of sprinkler systems.
  • 2CEA4001:2009 Sprinkler systems:planning and installation.
  • 3GB50084-2001.自动喷水灭火系统设计规范[S].[S].,..
  • 4GB 50084-2001(2005年版),自动喷水灭火系统设计规范.
  • 5核工业第二研究设计院.给水排水设计手册--建筑给水排水[M].2版.北京:中国建筑工业出版社,2001.

共引文献30

同被引文献6

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部