摘要 定电位电解法用于煤质活性炭活化炉烟气二氧化硫测试时,其结果与物料衡算法和红外法获得的结果之间存在显著性差异。活化炉烟气中普遍的高一氧化碳浓度可能是造成定电位电解法测试结果偏高的重要因素。 Sulfur dioxide (S02)emissions levels from flue gas activation furnace of the coal- based activated carbon detected by fix-potential electrolysis method show a significant differ- ence from that of method of balanced calculation between materials and products and the infrared method. The high concentration of carbon monoxide (CO)in the activation furnace flue gas may be an important factor that caused the high results detected by Fix-potential electrolysis method.
出处 《石油化工应用》 CAS 2012年第5期55-58,共4页 Petrochemical Industry Application
基金 国家环境标准制修订(2009-6-427)
关键词 定电位电解法 活化炉 二氧化硫 物料衡算法 红外法 fix -potential electrolysis method activation furnace sulfur dioxide method ofbalanced calculation between materials and products infrared method