摘要 用循环伏安法制备了银掺杂聚L-甲硫氨酸修饰玻碳电极,研究了对苯二酚和邻苯二酚在该修饰电极上的电化学行为,建立了同时测定对苯二酚和邻苯二酚的新方法。研究发现,在pH=5.0的磷酸盐缓冲溶液中,扫速为100 mV/s时,对苯二酚和邻苯二酚在银掺杂聚L-甲硫氨酸修饰玻碳电极上均出现1对氧化还原峰,峰电位分别为:Epa=0.228 V、Epc=0.162 V和Epa=0.347 V、Epc=0.287 V,二者的氧化峰电位差达119 mV,还原峰差达125 mV。在最佳的条件下,用差分脉冲伏安法同时测定邻苯二酚和对苯二酚的线性范围为3.00×10-6~1.00×10-4 mol/L,检出限为8.0×10-7 mol/L(对苯二酚)和5.0×10-7 mol/L(邻苯二酚)。此法用于废水样中对苯二酚和邻苯二酚的测定,获得满意结果。 A silver doped poly(L-methionine) modified glassy carbon electrode was fabricated through cyclic voltammetric method.The electrochemical behaviors of hydroquinone and catechol on the silver doped poly(L-methionine) modified electrode were investigated.In a phosphate buffer solution with pH=5.0,the modified electrode gave a pair of redox peaks at Epa=0.228 V,Epc=0.162 V for hydroquinone and Epa=0.347 V,Epc=0.287 V for catechol at the scan rates of 100 mV/s.Two peak differences for oxidation or reduction were 119 mV or 125 mV,respectively.Under optimized conditions,the oxidation peak currents were proportional to the concentrations of hydroquinone and catechol,respectively.The linear ranges for the simultaneous determination of hydroquinone and catechol using differential pulse voltammetry were 3.00×10-6~1.00×10-4 mol/L.The detection limits were 8.0×10-7 mol/L for hydroquinone and 5.0×10-7 mol/L for catechol,respectively.The as-established protocol was successfully applied for the simultaneous determination of hydroquinone and catechol in waste water samples with satisfactory results.
出处 《应用化学》 CAS CSCD 北大核心 2012年第5期576-584,共9页 Chinese Journal of Applied Chemistry
基金 安徽省高校省级自然科学研究重点项目基金资助项目(KJ2011A255)
关键词 银掺杂聚L-甲硫氨酸修饰电极 对苯二酚 邻苯二酚 同时测定 循环伏安法 差分脉冲伏安法 silver doped poly(L-methionine) modified electrode hydroquinone catechol simultaneous determination cyclic voltammetry differential pulse voltammetry
  • 相关文献

参考文献12

  • 1Zhao D M,Zhang X H,Feng L J,et al.Simultaneous Determination of Hydroquinone and Catechol at PASA/MWNTsComposite Film Modified Glassy Carbon Electrode[J].Colloids and Surf B,2009,74:317-321.
  • 2李淮芬,谢成根,宗佳佳,周汉坤.同步荧光法同时测定苯二酚中邻苯二酚和对苯二酚[J].冶金分析,2009,29(9):31-35. 被引量:19
  • 3黄少鹏,徐金瑞,王琼.薄层色谱法同时测定邻苯二酚、间苯二酚和对苯二酚异构体[J].分析化学,1999,27(3):331-333. 被引量:32
  • 4Yu J J,Du W,Zhao F Q,et al.High Sensitive Simultaneous Determination of Catechol and Hydroquinoneat MesoporousCarbon CMK-3 Electrode in Comparison with Multi-walledcarbon Nanotubes and Vulcan XC-72 Carbon Electrodes[J].Electrochim Acta,2009,54:984-988.
  • 5Ma W,Sun D M.The Electrochemical Properties of Dopamine,Epinephrine and Their Simultaneous Determination at APoly(L-methionine)modified Electrode[J].Russ J Electrochem,2007,43(12):1382-1389.
  • 6Hu W N,Sun D M,Ma W.Silver Doped Poly(L-valine)Modified Glassy Carbon Electrode for the SimultaneousDetermination of Uric Acid,Ascorbic Acid and Dopamine[J].Electroanalysis,2010,22(5):584-589.
  • 7Hu W N,Sun D M,Ma W.Simultaneous Electrochemical Determination of Dopamine and Epinephrine with a Silver DopedPoly(L-glutamic acid)Modified Glassy Carbon Electrode[J].Chem Anal(Warsaw),2008,53(5):703-716.
  • 8王广凤,李茂国,阚显文,高迎春,方宾.纳米银/半胱氨酸修饰金电极的制备及对苯二酚的测定[J].应用化学,2005,22(2):168-171. 被引量:17
  • 9王春燕,由天艳,田坚.聚谷氨酸修饰电极同时检测对苯二酚和邻苯二酚[J].分析化学,2011,39(4):528-533. 被引量:29
  • 10Sun W,Li Y Z,Yang M X,et al.Application of Carbon Ionic Liquid Electrode for the Electrooxidative Determination ofCatechol[J].Sensors Actuators B:Chem,2008,133:387-392.

二级参考文献46

共引文献80

同被引文献126

引证文献8

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部