摘要 合理的运行方式和及时有效的事故处理是提升电网安全的重要保障。文中从改进电网运行方式、提高调度实时监控能力出发,提出了基于广域测量系统(WAMS)的电网扰动监视、分析、评估、存储和离线研究的整体框架,并就相量测量单元(PMU)数据在电网扰动监视中的应用进行了比较分析。电网扰动时,不仅需要对扰动事件自身的性质进行分析,还需要对扰动后电网运行方式的变化、电网潮流和安全裕度的变化进行分析,并对扰动过程中机组调频等二次设备的动作响应行为进行评价,以期改进电网运行方式。对电网扰动过程信息进行集中式存储管理,则有助于方式离线研究和事故反演。 Rattonal operation mode and efficient fault handling are essential to power system security In order to optimize the power grid operation mode and improve scheduling real-time monitoring capability, an integrated framework is proposed tor WAMSrbased grid disturbance monitoring, analysis, evaluation, storage and offqine study in addition to a comparison and analysis of PMU data application in grid disturbance monitoring. When a grid disturbance occurs, not only should the principal features of the fault itself be analyzed, .but also the post-fault topology, power flow and security margin variation should be dealt with. And it's also important to evaluate the action response of the generator governor system and other secondary equipment in the power system. Furthermore, performing integrated management of power disturbances is helpful to o^f-hne research and replay.
出处 《电力系统自动化》 EI CSCD 北大核心 2012年第8期82-86,共5页 Automation of Electric Power Systems
关键词 广域测量系统 电网扰动 在线监视和评估 安全裕度 WAMS power system disturbance on-line monitoring and evaluation security margin
  • 相关文献

参考文献12

  • 1CAI J Y, HUANG Zhenyu, HAUER J, et al. Current status and experience of WAMS implementation in North America [C]// Proceedings of IEEE/PES Transmission and Distribution Conference and Exhibition, August 15-17, 2005, Dalian, China: 1 7.
  • 2IEEE 1588--2002 Standard for precision clock synchronization protocol for networked measurement and control svstemsFS: 2002.
  • 3I IEEE 1588--2008 Precision clock synchronization protocol for networked measurement and control systems[S]. 2008.
  • 4Q/GDW131--2006电力系统实时动态监测系统技术规范[S].2006.
  • 5IEEE 1344 1995 Standard for synchrophasors for power systems[S]. 1995.
  • 6IEEE C37. 118--2005 IEEE standard for synchrophasors for power systems[S]. 2005.
  • 7宋晓娜,毕天姝,吴京涛,杨奇逊.基于WAMS的电网扰动识别方法[J].电力系统自动化,2006,30(5):24-28. 被引量:43
  • 8姚建国,郑涛,高伏英,等.基于相量测量技术的电网扰动在线自动识别方法:中国,200710135097.7[P].2009—09—16.
  • 9Line outage detection using phasor angle measurements [EB/ OL]. [2011-07-01] http://www, pserc, wisc. edu/ecow/get/ publicatio/2007 pubtic/tate_overbye_pes nov2007, pdf.
  • 10高宗和,闪鑫,汪德星,等.基于相量测量技术的发电机一次调频实时定量分析方法:中国,200710135098.[P].200911-04.