采用吸收修正Bronnikov算法的有机复合样品的X射线显微计算机层析研究 被引量:6

Investigation on X-Ray Micro-Computed Tomography Suitable for Organic Compound Samples Based on Modifed Bronnikov Algorithm
原文传递
导出
摘要 有机复合样品如大多数由低原子序数物质构成的多聚物组合材料、生物软组织等具有混合相位和振幅特性,采用传统吸收计算机层析(CT)或纯相位重构算法难以达到较高密度分辨的目的。采用基于吸收修正的Bronnikov相位恢复算法的X射线同轴相衬CT技术对高分子混合组份材料和药物医学样品进行了实验研究。结果表明该相位恢复算法可以实现多聚物组合材料的无损分辨和精确测量,能够清晰辨别各组份材料的电子密度分布;验证了药物样品多孔性结构三维测量的可行性,能够有效提供孔隙测量的阈值选择。该方法在材料科学尤其是聚合物组合材料、泡沫多孔材料都会发挥很好的作用;单距的低辐射优势,尤其适用于生物医学样品三维无损成像。 Organic compound samples are characterized by mixed phase and amplitude,such as most polymer combination materials and biological soft tissues made from low-atomic-number materials etc,which are very hard to obtain higher resolution of density by conventional absorption computerized tomography(CT) or phase retrival algorithm of pure-phase object.The X-ray in-line phase contrast CT technology based on the modified Bronnikov algorithm has been utilized for the experimental investigation of high polymer mixed materials and medical samples.The experimental results show that the proposed method can realize the non-destructive imaging and precise measurement of polymer combination samples by distinguishing those electronic densities of different parts clearly.In addition,the results demonstrate the feasibility of three-dimensional measurement of medical samples with porosity by supplying with a valid threshold.The method has good potential application in material science,especially in polymers and foam porous materials,and three-dimensional nondestructive imaging of biomedicine due to the advantage of low radiation dose.
出处 《光学学报》 EI CAS CSCD 北大核心 2012年第4期320-326,共7页 Acta Optica Sinica
基金 国家973计划(2010CB834301) 国家自然科学基金(10805071 10705020 11105213) 中国科学院对外合作重点项目(GJHZ09058) 上海市基础研究重点项目(08JC1411900)资助课题
关键词 X射线光学 相位恢复 X射线同轴相衬计算机层析 定量密度分辨 X-ray optics phase retrieval X-ray in-line phase contrast computerized tomography quantitative density resolution
  • 相关文献

参考文献18

  • 1R.C.Chen,H.L.Xie,L.Rigon et al..Phase retrieval inquantitative X-ray microtomography with a single sample-to-detector distance[J].Opt.Lett.,2011,36(9):1719-1721.
  • 2A.Groso,M.Stampanoni,R.Abela.Phase contrasttomography:an alternative approach[J].Appl.Phys.Lett.,2006,88(21):214104.
  • 3A.Groso,R.Abela,M.Stampanoni.Implementation of a fastmethod for high resolution phase contrast tomography[J].Opt.Express,2006,14(18):8103-8110.
  • 4Andrei V.Bronnikov.Theory of quantitative phase-contrastcomputed tomography[J].J.Opt.Soc.A,2002,19(3):472-480.
  • 5R.C.Chen,R.Longo,L.Rigon et al..Measurement of thelinear attenuation coefficients of breast tissues by synchrotronradiation computed tomography[J].Phys.Med.Biol.,2010,55(17):4993-5005.
  • 6M.Boone,Y.De Witte,M.Dierick et al..Practical use of themodified Bronnikov algorithm in micro-CT[J].NuclearInstruments and Methods in Physics Research Section B,2009,267(7):1182-1186.
  • 7Yuqi Ren,Can Chen,Rongchang Chen et al..Optimization ofimage recording distances for quantitative X-ray in-line phasecontrast imaging[J].Opt.Express,2011,19(5):4170-4181.
  • 8S.Zabler,P.Cloetens,J.P.Guigay et al..Optimization ofphase contrast imaging using hard X rays[J].Rev.Sci.Instrum.,2005,76(7):073705.
  • 9J.P.Guigay,M.Langer,R.Boistel et al..Mixed transferfunction and transprot of intensity approach for phase retrieval inthe Fresnel region[J].Opt.Lett.,2007,32(12):1617-1619.
  • 10M.Langer,P.Cloetens,F.Peyrin.Fourier-waveletregularization of phase retrieval in X-ray in-line phase tomography[J].J.Opt.Soc.Am.A,2009,26(8):1876-1881.

二级参考文献87

共引文献48

同被引文献73

引证文献6

二级引证文献66

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部