摘要 应用工业电除尘的原理,采用正离子浸润灭菌和镜象力荷电吸附除菌,只考虑细菌尘粒的粒径,不考虑其生物性的技术路线,设计了一种小型的组合式静电场装置,配以高频高压恒流电源的室内空气洁净器,在面积20m^2,高3m的室内使用,可达到1万级洁净度(0.5μm粒子浓度<35O个/L)。医院手术室和重症监护病房的应用实例结果表明,具有在有人场合下连续消毒除菌和去除异味的优点。 Applying the principle of industrial electric dedusting and adopting posotive ion infiltrated bacteria and 'mirror image force electric charge' to absorb and eliminate bacteria only considering particle size of bacteria and not their biological technical route, to design a kind of mini-assembling electrostatic device with power supply of high frequency and high voltage constant current indoor air cleaner and with 20m2 surface area and 3m height, use in indoor, can be able to meet 10 thousand grade cleaning (particle concentration of 0.5um less than 350/L). The experimental result when applied to operation room, intensive care unit, delivery room etc. showed that the device which applied continously to public places could eliminate bacteria and malodour effectively.
出处 《上海环境科学》 CAS CSSCI CSCD 2000年第4期171-173,175,共4页 Shanghai Environmental Sciences
关键词 静电除法 空气净化消毒 空气洁净器 MKJ型 Electrostatic precipitation Indoor air disinfection and cleaning Air cleaner
  • 相关文献

参考文献2

  • 1切雷米西诺夫 P N,大气污染控制设计手册,1986年
  • 2许钟麟,空气洁净技术原理,1983年

同被引文献28

  • 1王锡录,马福荣,陈立宏,王希英,许继增,杨雪峰,荣大奇.用静电高压法杀灭枯草杆菌[J].东北师大学报(自然科学版),1993,25(4):40-44. 被引量:3
  • 2石连仲,王晓燕,姚玉虹,李春梅,钱志敏.空气消毒洁净器对手术室空气消毒效果评价[J].中华医院感染学杂志,2004,14(9):1022-1022. 被引量:5
  • 3王锡录,徐明华.静电高压杀灭表皮葡萄球菌的研究[J].静电,1996,11(1):13-15. 被引量:5
  • 4王茂章 贺福.炭纤维的制造性能及其应用[M].北京:科学出版社,1984..
  • 5麦金太尔(英) 龙惟定 殷平 夏清.室内气候[M].上海:上海科学技术出版社,1988..
  • 6麦金太尔(英).室内气候[M].上海科学技术出版社,1988..
  • 7Sale A. J. H., Hamilton W A. Effects of high electric fields on microorgamism. Biochim Biophys Acta[J]. 1968,163:37~43.
  • 8Tsong T. Y. Electropration of cell membranes, Biophys J. [J].1991,60:297~306.
  • 9Zimmermann U. Electric Breakdown Electropenmeabilization and Electrofusion Rev. Phys Biochem Phamacol[J].1986,105:196~256.
  • 10Wang SY,He FZ,Luo KH.Study of the Effect of the Rapid-Effect Air Disinfectant Tablet in the Sterilization of Hospital Air[J].Zhonghua Hu Li Za Zhi,1997,32(1):37-38.