摘要
分析岭澳核电站二期反应堆核测量各相关系统的主要特点,阐述核仪表系统(RPN)、堆芯中子注量率测量系统(RIC)、冷却剂丧失事故(LOCA)监测系统(LSS)与数字化仪表控制系统(DCS)的功能划分和接口设计方案。岭澳核电站二期设计方案针对RPN、RIC、LSS不同的功能需求和特点,有效地利用数字化仪表控制平台的优势,灵活采用3种与DCS的功能分配和接口划分方案,更好地实现了故障诊断和逻辑功能处理。
This paper analyzes the characteristics of Reactor Nuclear Measurement Systems,including Nuclear Instrumentation System(RPN),In-core Neutron Fluence Rate Measurement system(RIC),LOCA Surveillance System(LSS),and introduces the function distribution and interface design between the Nuclear Measurement Systems and the Digital Instrument Control System(DCS).Based on the advantages of DCS,3 different function distribution and interface design schemes are taken in Ling'ao Nuclear Power Station Phase Ⅱ for different function requirements and characteristics of RPN,RIC and LSS.Consequently,these design schemes lead to a good result in fault diagnosis and logic processing.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
2012年第2期1-4,共4页
Nuclear Power Engineering
关键词
岭澳核电站二期
核测量系统
功能分配
接口
Ling'ao nuclear power station phase II
Nuclear measurement systems
Function distribution
Interface