期刊文献+

股骨远端LISS钢板固定钉道及远端贴附三维数字化模拟 被引量:2

Digital anatomy of the distal femoral fixation with LISS plate
原文传递
导出
摘要 目的利用三维数字化重建和逆向工程技术,将LISS钢板与国人股骨远端重建模型匹配,并测量螺钉钉道参数,并探索一种个性化钢板固定手术方法。方法选自内蒙古医学院第二附属医院影像科非膝关节疾患成人CT连续扫描数据15例,共30侧(股骨大转子下缘至胫骨上1/3,年龄18~41岁,平均32岁),通过将重建钢板和螺钉导入Mimics10.01系统中与重建股骨远端进行配准,测量钢板钉孔位置上螺钉钉道长并检测钢板与股骨远端骨面贴附状况。结果螺钉钉道长度逐渐增大;重建股骨与钢板贴附实验中,左侧5例不能贴附,右侧7例不能贴附。结论 LISS钢板固定股骨中远端,钉道由上到下逐渐增长,其长度有规律可循,现有产品规格与国人股骨远端解剖参数尚存在一定差异,需进一步改良。 Objective To provide a basis on operation of distal femoral fracture by measuring screw canal parameters of distal femoral fixation using digital 3D skill and reverse engineering.Methods 15 adult cases(CT data came from the second affiliated hospital of Inner Mongolia medical college,without knee joint illness,extending from the lower of greater trochanter of femur to the upper 1/3 of tibia,ranging from 18~41 years,averagely 32 years old)were 3D reconstructed,including nail canal digital simulation and fixation.Results For 3D model of distal femur,the canal of screws gradually increased.5 cases were not fit in left and 7 cases in right.Conclusions The screw canal,which is less invasive stable system for distal femur,is regular,with the gradually increased length.The parameters of LISS are differ from anatomic features of Chinese distal femur,and the improvement of LISS is necessary.
出处 《中国临床解剖学杂志》 CSCD 北大核心 2012年第2期169-172,共4页 Chinese Journal of Clinical Anatomy
关键词 股骨远端 解剖型钢板 LISS 数字解剖 Distal femur Anatomical steel LISS Digital anatomy
  • 相关文献

参考文献21

  • 1Lohiya R,Bachhal V,Khan U,et al.Flexible intramedullary nailing inpaediatric femoral fractures.A report of 73 cases[J].J Orthop Surg Res,2011,6(1):64.
  • 2Vallier HA,Immler W.Comparison of the 95-degree angled blade plateand the locking condylar plate for the treatment of distal femoralfractures[J].J Orthop Trauma,2011,PMID:22183200.[Epub ahead ofprint].
  • 3Olkowski AA,Laarveld B,Wojnarowicz C,et al.Biochemical andphysiological weaknesses associated with the pathogenesis of femoralbone degeneration in broiler chickens[J].Avian Pathol,2011,40(6):639-650.
  • 4Ellis HB,Ho CA,Podeszwa DA,et al.A comparison of locked versusnonlocked enders rods for length unstable pediatric femoral shaftfractures[J].J Pediatr Orthop,2011,31(8):825-833.
  • 5Rohilla R,Singh R,Rohilla S,et al.Locked intramedullary femoralnailing without fracture table or image intensifier[J].Strategies TraumaLimb Reconstr,2011,6(3):127-135.
  • 6Dubov A,Kim SY,Shah S,et al.The biomechanics of plate repair ofperiprosthetic femur fractures near the tip of a total hip implant:theeffect of cable-screw position[J].Proc Inst Mech Eng H,2011,225(9):857-865.
  • 7Shah S,Kim SY,Dubov A,et al.The biomechanics of plate fixation ofperiprosthetic femoral fractures near the tip of a total hip implant:cables,screws,or both[J] ?Proc Inst Mech Eng H,2011,225(9):845-856.
  • 8Wilson LJ,Richards CJ,Irvine D,et al.Risk of periprosthetic femurfracture after anterior cortical bone windowing[J].Acta Orthop,2011,82(6):674-678.
  • 9Macovei L,Ancua C,Belibou C,et al.Bone mineral density in patientswith rheumatoid arthritis[J].Rev Med Chir Soc Med Nat Iasi,2011,115(3):723-730.
  • 10Chou DT,Taylor AM,Boulton C,et al.Reverse obliqueintertrochanteric femoral fractures treated with the intramedullary hipscrew(IMHS)[J].Injury,2011,PMID:22040693.

二级参考文献11

共引文献1

同被引文献21

  • 1朱式仪,孙广生,申光宪,张俊琪.人工桡骨头假体的研制和临床应用[J].中华实验外科杂志,1994,11(6):377-377. 被引量:1
  • 2Arbter D, Piatek S, Probst A, et al. Results after ]udet radial head pros- thesis for non-reconstructable radial head fractures. Unfallchirurg, 2012, 115(11): 1000-1008.
  • 3Flinkkil[i T, Kaisto T, Sirni6 K, et al. Short- to mid-term results of metallic press-fit radial head arthroplasty in unstable iniuries of the elbow. ] Bone ]oint Surg (Br), 2012, 94(6): 805-810.
  • 4苏秀云,刘蜀彬.Mimics软件临床应用.北京:人民军医出版社2011:73—212.
  • 5尹庆水,章莹,王成焘,等.临床数字骨科学.北京:人民军医出版社201l:164-168.
  • 6van Riet RP, van Glabbeek F. History of radial head prosthesis in trau- matology. Acta Orthop Belg, 2007, 73(1): 12-20.
  • 7King G], Zarzour ZD, Patterson SD, et al. An anthropometric study of the radial head. ] Arthroplasty, 2001, 16(1): 112-116.
  • 8Schmidt-Horloh6 K, Siebenlist S, St6clde U, et al. Fractures of the ra- dial head and neck. Z Orthop Unfall, 2011,149(6): e69-86.
  • 9Bly RA, Chang SH, Cudejkova M, et al. Computer-guided orbital reconstruction to improve outcomes. JAMA Facial Plast Surg, 2013, 15(2): 113-120.
  • 10Schulz AP, Reimers N, Wipf F, et al. Evidence based development of a novel lateral fibula plate (variAx fibula) using a real CT bone data based optimization process during device development. Open Orthop J, 2012, 6: 1-7.

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部