Marx发生器同步性对PTS装置性能的影响 被引量:8

Effect of synchronization of Marx generators on primary test stand
在线阅读 下载PDF
导出
摘要 对PTS装置的24台Marx发生器进行了独立调试实验,实验结果表明:在充电电压60kV、工作欠压比62%条件下,24台Marx发生器的输出电压的时延在245~285ns的范围内,时延最大差异为40ns,时延抖动均小于10ns。通过对PTS装置控制时序和中间储能器充电电压波形的分析,认为Marx发生器输出电压的时延差异在50ns内,中间储能器上总的电压损失小于1%,对主开关的工作状态基本上没有影响。 The tests of 24 Marx generators on the primary test stand(PTS) have been carried out.When the charging voltage is 60 kV and the working ratio is 62%,the delay time of output voltage for 24 Marx generators ranges from 245 to 285 ns with a total spread of 40 ns and individual jitters less than 10 ns.The timing diagram of the PTS control system and the charging waveform of the intermediate storage capacitor are analyzed.When the spread of delay time for output voltage of 24 Marx generators is 50 ns,the voltage loss of intermediate storage capacitor is less than 1% and it has no effect on the operation state of the main switch.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2012年第3期685-688,共4页 High Power Laser and Particle Beams
基金 国家自然科学基金重点项目(10635050 50827004)
关键词 MARX发生器 时延 抖动 电压损失 Marx generator delay time jitter voltage loss