期刊文献+

Delta陶瓷人工假体在全髋关节置换术中的应用效果观察 被引量:9

暂未订购
导出
摘要 目的观察Delta陶瓷人工假体在全髋关节置换术的近期应用效果。方法对56例(61髋)严重髋关节疾病患者行Delta陶瓷对陶瓷人工假体全髋关节置换术。采用Harris评分标准对髋关节功能进行评定。通过双髋正位X线片,测量髋臼外展角和估算前倾角,观察有无陶瓷碎裂、假体脱位、假体周围透亮线和骨溶解、假体松动、感染及假体周围骨折情况发生。结果手术时间为55~90 min,术中出血量120~200 mL,术后引流量150~400 mL。术后平均随访1年7个月。术后1年,Harris髋关节评分为(89.3±7.9)分,明显高于术前的(40.3±10.5)分(P<0.01)。髋关节功能优37例,良18例,可1例。X线检查示髋臼外展角42.7°±2.6°,前倾角为19.6°±3.5°。随访期间无关节异响发生,未见陶瓷碎裂、假体脱位、骨溶解形成及假体松动、移位和下沉,无感染和假体周围骨折的发生。1例术后6个月时出现髋关节周围异位骨化,关节功能良好。结论 Delta陶瓷人工假体全髋关节置换术治疗严重髋关节疾病的近期疗效满意。
出处 《山东医药》 CAS 2012年第10期36-38,共3页 Shandong Medical Journal
  • 相关文献

参考文献14

  • 1Lusty PJ,Tai CC,Sew-Hoy RP. Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty[J].Journal of Bone and Joint Surgery-American Volume,2007,(12):2676-2683.doi:10.2106/JBJS.F.01466.
  • 2Capdlo WN,D'Antonio JA,Feinberg JR. Ceramic-on-ceramic total hip arthroplasty:update[J].Journal of Arthroplasty,2008.39-43.
  • 3Petsatodis GE,Papadopoulos PP,Papavasiliou KA. Primary cementless total hip arthroplasty with an alumina ceramic-on-ceramic bearing:results after a minimum of twenty years of follow-up[J].Journal of Bone and Joint Surgery-American Volume,2010,(03):639-644.doi:10.2106/JBJS.H.01829.
  • 4Chevillotte C,Pibarot V,Carret JP. Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty[J].International Orthopaedics,2011,(11):1599-1604.
  • 5Sugano N,Takao M,Sakai T. Eleven-to 14-year Follow-up Results of Cementless Total Hip Arthroplasty Using a Third-generation Alumina Ceramic-on-ceramic Bearing[J].Journal of Arthroplasty,2011.
  • 6Hannouche D,Zaoui A,Zadegan F. Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty[J].International Orthopaedics,2011,(02):207-213.doi:10.1007/s00264-010-1187-1.
  • 7Al-Hajjar M,Leslie IJ,Tipper J. Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX delta ceramic-on-ceramic total hip replacement[J].Journal of Biomedical Materials Research Part B:Applied Biomaterials,2010,(02):263-268.
  • 8Kim YH,Choi Y,Kim JS. Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis[J].International Orthopaedics,2010,(08):1123-1127.doi:10.1007/s00264-009-0878-y.
  • 9Hannouche D,Nich C,Bizot P. Fractures of ceramic bearings:history and present starus[J].Clinical Orthopaedics and Related Research,2003.19-26.
  • 10Mai K,Verioti C,Fzzet KA. Incidence of squeaking after ceramic-on-ceramic total hip arthroplasty[J].Clinical Orthopaedics and Related Research,2010,(02):413-417.doi:10.1007/s11999-009-1083-4.

同被引文献130