期刊文献+

Schick数字化成像系统的临床应用及图片效果分析

Clinical application of Schick digital imaging system and its image quality evaluation
原文传递
导出
摘要 目的:探讨Schick数字化成像系统的临床应用,评价Schick数字化成像系统的成像质量。方法:随机选取Schick数字化成像系统所拍X线根尖片和Kodak根尖胶片各200张,比较其曝光时间和X线垂直角度,对其成像质量进行分级评价。结果:Schick数字化成像系统所拍根尖片成像质量Ⅰ级者为90%,比Kodak根尖胶片高25%;Schick数字化成像系统所拍根尖片成像质量Ⅲ级和Ⅳ级所占比例为5%,与Kodak根尖胶片无明显差别。结论:采用Schick数字化成像系统拍摄根尖片成像质量优良,能较好地满足临床应用要求。 Objective:To explore the clinical application of Schick digital imaging system and evaluate its image quality. Method: 200 images of Kodak periapical films and 200 periapical film images taken by Schick digital imaging system were Randomly selected,the exposure time and x-ray vertical angle were compared,and the image quality was graded and assessed. Result: Grade I of periapical film images taken by Schick digital imaging system was 90 %, which was 25 % higher than Kodak periapical films. Grade III and IV of periapical film images taken by Schick digital imaging system was 5 % ,with no significant difference compared to Kodak periapical films. Conclusion:The periapical film images quality of Schick digital imaging system was fine, and could meet the clinical requirements.
出处 《临床口腔医学杂志》 2012年第4期225-227,共3页 Journal of Clinical Stomatology
关键词 数字化成像系统 根尖片 评价 digital imaging system periapical film evaluate
  • 相关文献

参考文献11

二级参考文献28

  • 1杨午.X线技术数字化和放射学“多媒体高速公路”[J].中国医疗器械杂志,1996,20(1):39-42. 被引量:5
  • 2乔文龙,黄惠如.数字X线摄影及其临床应用[J].中国医疗器械杂志,1996,20(2):98-99. 被引量:10
  • 3范占明,曾庆玉,刘钟生,霍健伟,白林,罗凌飞,班润义,王惠芝.数字化多用途X线透视系统临床应用价值[J].中国医学影像学杂志,1996,4(3):174-176. 被引量:4
  • 4Soltani P. Digital radiography for the New Millennium. Digital Imaging Ⅲ, 2000,Aug.
  • 5Chaussat C,Chabbal J, Ducourant, et al. "New CSI/a- sil7" Xray Flat panel detector provides superior detectivity and immediate direct digital output for General Radiography systems. Proc. of SPlE, 1998, 3336:45.
  • 6Artz DS. Computed radiography for the radiological technologist. Serain Roentgenol. 1997,10 : 12.
  • 7Leblans P. A new needle-crystalline computed radiography detector.J Digit Imaging. 2000,13 : 117.
  • 8Spahn M. Digital radiography with a largearea, amorphous-silicom,fiat-panel X-ray detector system, Invest Radiol. 2000, 35:260.
  • 9Workan A, Cowen AR. Improved image quality utilizing dual plate computed radiography. Br J Radiol. 1995, 68:182.
  • 10Shaw CC, Wang TP, Breitenstein DA. Improvement of slgnal-tonoise and contrast-to-noise ratios in dual-screen computed radiography. Med phys. 1997, 24:1293.