期刊文献+

帝视内镜与直接喉镜对患者气管插管血流动力学影响的比较 被引量:49

The clinic observation of endotracheal intubation with discope intubating device versus macintosh direct laryngoscope in general anesthesia patients
原文传递
导出
摘要 目的观察帝视内镜与直接喉镜气管内插管时对患者血流动力学的影响。方法非心肺疾病及困难气道择期手术患者80例,随机分为帝视内镜组(DISCOPO组)和直接喉镜组(MDLS组),每组40例。记录麻醉前基础值(T1)、麻醉诱导后插管前(T2)、插管成功即刻(T3)及插管后1 min(T4)、5 min(T5)的SBP、DBP、MAP、HR、气管插管操作时间,计算心率收缩压乘积(RPP)。结果两组均顺利完成气管内插管。组内比较,DISCOPO组内,与T1时比较,T2时MAP和RPP都明显降低,差异有统计学意义(P<0.05);T3和T4时的MAP和RPP升高,但差异无统计学意义(P>0.05);而HR指标比较,差异均无统计学意义(P>0.05)。MDLS组内,与T1时比较,T2时MAP和RPP都明显降低,差异有统计学意义(P<0.05);T3和T4时的MAP、RPP和HR显著升高(P<0.05)。两组间比较,T3、T4时,MDLS组MAP、HR、RPP指标明显高于DIS-COPO组,差异有统计学意义(P<0.05)。结论帝视内镜、直接喉镜气管插管对血流动力学均有影响,帝视内镜气管插管反应较轻。 Objective To investigate the hemodynamic responses to endotracheal intubation with discope intubating device versus macintosh direct laryngoscope(MDLS)in general anesthesia patients.Methods Eighty adult patients without difficult airways or cardiopulmonary diseases and scheduled for time-selective surgery under general anesthesia were randomly assigned to one of two groups(n=40 for each).The discope group received tracheal intubation with discope,while the MDLS group with macintosh direct laryngoscope.Changes in systolic blood pressure(SBP),diastolic blood pressure(DBP),mean airway pressure(MAP),heart rate(HR)and tracheal intubation time were measured before anesthesia induction(T1),after anesthesia induction(T2),immediately after intubation(T3),1 minute after intubation(T4)and 5 minutes after intubation(T5).Rate pressure product(RPP)were calculated.Results All procedures were successful on the first attempt.Compared with pre-induction(T1),MAP and RPP in both two groups significantly decreased after anesthetic induction(P0.05).However,compared with T1,MAP and RPP did not increase significantly(P0.05)at T3 and T4 in discope group,while MAP,RPP and HR did increase significantly(P0.05)at T3 and T4 in MDLS group.The HR at T1,T2,T3,T4 and T5 in discope group did not change remarkably(P0.05).In MDLS group,MAP,HR and RPP at T3 and T4 were significant higher than those in scope group(P0.05).Conclusions In comparison to Macintosh direct laryngoscope,tracheal intubation with discope laryngoscope resulted in less alterations in hemodynamic responses.
出处 《中华临床医师杂志(电子版)》 CAS 2012年第4期I0015-I0017,共3页 Chinese Journal of Clinicians(Electronic Edition)
关键词 内窥镜 喉镜 插管法 气管内 血流动力学 Endoscopes Laryngoscopes Intubation intratracheal Hemodynamics
  • 相关文献

参考文献2

二级参考文献14

  • 1丁希喆,王祥瑞.GlideScope~视频喉镜在麻醉气管插管中的应用[J].上海交通大学学报(医学版),2007,27(2):206-208. 被引量:40
  • 2McCollum JS, Dundee JW. Comparison of induction characteristics of four intravenous anaesthetic agents. Anaesthesia, 1986, 41:995-1000.
  • 3Takahashi S, Mizutani T, Miyabe M, et al. Hemodynamic responses to tracheal intubation with laryngoscope versus lightwand intubating device (Trachlight) in adults with normal airway. Anesth Analge, 2002,95 : 480-484.
  • 4Kanaide M, Fukusaki M,Tamura S, et al. Hemodynamic and catecholamine responses during tracheal intubation using a lightwand device (Trachlight) in elderly patients with hypertension. J Anesth, 2003,17 : 161-165.
  • 5Cooper RM. Use of a new videolaryngoscope (Glide Scope ) in the management of a difficult airway. Can J Anaesth,2003,50:611-613.
  • 6Agro F, Barzoi G, Montecchia F. Tracheal intubation using a Macintosh laryngoscope or a GlideScope in 15 patients with cervical spine immobilization. Br J Anaesth, 2003,90: 705-706.
  • 7Doyle DJ. Awake intubation using the GlideSeope video laryngoscope: initial experience in four eases. Can J Anaesth,2004,51:520-521.
  • 8Lim Y, Lim TJ, Liu EH. Ease of intubation with the GlideScope or Macintosh laryngoscope by inexperienced operators in simulated difficult airways. Can J Anaeath,2004, 51:641-642.
  • 9Hirabayashi Y, Hiruta M, Kawakami T, et al. Effects of lightwand (Trachlight)compared with direct laryngoscopy on circulatory responses to tracheal intubafion. Br J Anaesth, 1998,81 : 253-255.
  • 10Adachi YU, Satomoto MS, Higuchi H,et al. Fentanyl attenuates the hemodynamic response to endotracheal intubation more than the response to laryngoscopy. Anesth Analg, 2002,95 : 233-237.

共引文献100

同被引文献308

引证文献49

二级引证文献144

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部