摘要 本文研究了励磁系统附加调差对系统阻尼的影响。将附加调差引入菲利蒲-海佛隆模型,分析附加调差对模型参数的影响。推导出附加调差提供的阻尼转矩系数增量ΔKD随附加调差系数XC变化的曲线为一条二次抛物线,而且这条抛物线的开口方向和位置与励磁参数、发电机参数、运行状况及系统参数有关。证明了此抛物线在以ΔKD为纵轴、以XC为横轴的坐标系中必经过原点,在其他参数确定的前提下,抛物线与横轴的第二个交点是发电机功角的函数。根据此抛物线可全面说明附加调差对系统阻尼的影响情况。现场试验结果与理论推导相符。 Based on the single-machine-infinite-bus system,the effect of Reactive Current Compensation(RCC) on the system damping is studied.First of all,RCC is added into the Phillips-Heffron model and the influence on the model and parameters caused by RCC is analyzed.Then the study proves that the relationship of the damping torque coefficient increment(ΔKD) provided by RCC and RCC coefficient(XC) is a second-degree parabola.Furthermore the open direction and position of the parabola are related with the excitation parameters,the parameters and the operating conditions of the generator and the system parameters.Finally the conclusion is given: the parabola passes through the zero point in the coordinate system whose abscissa axis is XC and vertical axis is ΔKD,and the second crossing point between the parabola and the abscissa axis will change with the power angle of generator if the other parameters are determinate.The effect of RCC on the dynamic damping can be explained comprehensively based this parabola.The field test result is in concord with the analysis.
出处 《大电机技术》 北大核心 2012年第2期53-57,共5页 Large Electric Machine and Hydraulic Turbine
关键词 励磁系统 附加调差 菲利蒲-海佛隆模型 阻尼 同步转矩 阻尼转矩 excitation system reactive current compensation philips-heffron model damping synchronous torque damping torq
  • 相关文献

参考文献1

二级参考文献12

  • 1KUNDUR P.电力系统稳定与控制[M].周孝信,译.北京:中国电力出版社,2002.
  • 2Murdoch A,Sanchez-Gasca J J,D Antonio M J,et al.Excitation control of high side voltage regulation[C].Proceedings of 2000 IEEE Power Engineering Society Summer Meeting,Seattle,Washington,USA,2000.
  • 3Hitomi Kitamura,Masaru Shimomura,John Paserba.Improvement of voltage stability by the advanced high voltage control regulator[C].IEEE Summer meeting-2000.Seattle,Washington,USA,2000.
  • 4Carson W.Tarlor.Line Drop Compensation,High side voltage control -why not control a generator like a static var compensator[C].Proceedings of 2000 IEEE Power Engineering Society Summer Meeting,Seattle,Washington,USA,2000.
  • 5Davies J B,Midford L E.High side voltage control at manitoba hydro[C].Proceedings of 2000 IEEE Power Engineering Society Summer Meeting,Seattle,Washington,USA,2000.
  • 6Dmitry Kosterev.Design,installation,and initial operating experience with line drop compensation at John Day powerhouse[J].IEEE Transaction on Power System,2001,16(2):261-265.
  • 7李兴源,段海峰.改善电压稳定性的发电机非线性最优变目标励磁控制[J].中国电机工程学报,1998,18(3):208-211. 被引量:4
  • 8孙元章,姚小寅,刘锋.二级电压控制对电力系统稳定性的影响[J].中国电机工程学报,2000,20(2):28-32. 被引量:27
  • 9周晓渊,邱家驹,陈新琪.高压侧电压控制对单机-无穷大系统稳定性的影响[J].中国电机工程学报,2003,23(1):60-63. 被引量:32
  • 10王琦,周双喜,朱凌志.采用高压侧电压控制改善系统的角度稳定性[J].电网技术,2003,27(6):19-21. 被引量:16

共引文献22

同被引文献59

引证文献6

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部