期刊文献+

三选二冗余测量技术在水电机组调速系统中的应用研究 被引量:3

Applied Research on the Redundant Measurement Technology of Picking Two from Three in the Governing System of Large Hydro-power Generating Units
在线阅读 下载PDF
导出
摘要 针对大型水电机组调速器导叶反馈故障导致的事故,本文分析了目前采用的双冗余导叶反馈测量方式存在的某些不足,提出了导叶反馈信号三选二的冗余测量方法,并从硬件设计上给出了具体方案,同.时也从软件设计上进行了详细分析并提出了相关应用策略。作者认为采用该模式能进一步提高系统的安全性及可靠性。 Aiming at the accident was due to the guide vane feedback faults of governor of large hydro-power generating units, this paper analyzes the existing certain shortcomings of the mode of dual redundant guide vane feedback measurement, which is adopted at present, proposes the redundant measuring method of picking two from three for the guide vane feedback signals, and gives the specific scheme in the hardware design, meanwhile, analyzes in detail the software design and puts forward the relevant application strategy as well. The authors consider that the safety and reliability of the system could be further improved by using this mode.
出处 《自动化信息》 2012年第3期54-56,共3页 Automation Information
关键词 导叶反馈 调速器 三选二冗余测量 故障判断 表决法 Guide Vane Feedback Governor Redundant Measurement of Picking Two from Three Fault Estimating Method of Deciding by Vote