摘要 背景:36mm大直径陶瓷球头较28mm常规直径陶瓷头增加了跳越距离,具有活动范围大,稳定性好,脱位率低等特点,适用于年轻,要求活动范围大,追求高生活质量患者。目的:观察36mm大头径陶瓷-陶瓷全髋关节假体行关节置换的早期疗效。方法:2009-06/2010-07采用Depuy公司的Pinnacle TM36mm大头径陶瓷-陶瓷全髋假体行初次人工全髋关节置换治疗18例(18髋)髋关节疾病患者。对照组为同期行Pinnacle TM28mm直径陶瓷-陶瓷人工全髋关节置换治疗20例(20髋)髋关节疾病患者。结果与结论:所有患者均获得随访,随访时间13~26个月。置换后切口均Ⅰ期愈合,未发生假体脱位、感染及下肢深静脉血栓形成等并发症。两组患者置换后Harris各项评分较置换前均明显改善(P<0.05),且直径36mm组置换后活动范围评分较直径28mm组改善明显(P<0.05);但两组置换后Harris总评分及疼痛、功能评分比较差异无显著性意义(P>0.05)。结果初步表明现代陶瓷-陶瓷人工关节假体能有效减少因关节界面磨损导致的骨溶解及关节松动等并发症。36mm大头径陶瓷-陶瓷全髋假体设计具有活动范围大,稳定性好,脱位率低等特点,在术中条件允许情况下,可作为首选型号。 BACKGROUND:36 mm large diameter of femoral head increases more jump distance than 28 mm diameter of femoral head,which has the characteristics of large range of motion,good stability and few dislocations.It can be appied to young patients,requiring large activities range and high quality of life.OBJECTIVE:To observe early clinical efficacy of 36 mm diameter of femoral head in ceramic-on-ceramic total hip arthroplasty.METHODS:From June 2009 to July 2010,18 hips in 18 patients with hip disease were treated with total hip arthroplasty using Depuy PinnacleTM 36 mm diameter of large femoral head in ceramic-on-ceramic total hip prosthesis.Control group (20 cases) were treated by total hip arthroplasty with Depuy PinnacleTM 28 mm diameter of femoral head in ceramic-on-ceramic total hip prosthesis in the same period.RESULTS AND CONCLUSION:All the patients were followed up from 13 months to 26 months,incisions got primary healing without complications such as prosthesis dislocation,infection and deep venous thrombosis postoperation.Postoperative total Harris score of the two groups was more significant improved as compared with those of the two groups preoperative (P〈0.05).Postoperative range of motion score in the 36 mm group was improved more significantly than that in the 28 mm group (P〈0.05).However,the two groups had no significant difference in postoperative total Harris score,pain score and function score (P〉0.05).Modern ceramic on ceramic hip prosthesis can effectively decrease the complications of osteolysis and prosthetic loosening caused by wearing of joint interface.36 mm diameter of femoral head in ceramic-on-ceramic total hip arthroplasty has the characteristics of large range of motion,good stability and few dislocations.It can be used as the first choice if the intraoperative conditions permit.
出处 《中国组织工程研究》 CAS CSCD 2012年第9期1559-1563,共5页 Chinese Journal of Tissue Engineering Research
  • 相关文献

参考文献2

二级参考文献26

  • 1Boutin P. Total arthroplasty of the hip by fritted alurninunl prosthesis. Experimental study and 1st clinical applications. Rev Chir Orthop Reparatrice Appar Mot, 1972, 58(3) :229-246
  • 2Clarke IC. Role of ceramic implants. Design and clinical success with total hip prosthetic ceramic-to-ceramic bearings. Clin Orthop, 1992; 282:19-30
  • 3Saikko VO, Paavolainen PO, Slatis P. Wear of the polyethylene acetabular cup. Metallic and ceramic heads compared in a hip simulator. Acta Orthop Scand,1993,64(4) :391-402
  • 4Sedel L, Kerboull L, Christd P, et al. Alumina-on-alumina hip replacement. Results and survivorship in young patients. J Bone Joint Surg Br, 1990,72(4):658-663.
  • 5Fisher J, Calvin A, Tipper J, et al. Comparison of the functional biological activity and osteolytic potential of ceramic on ceramic and cross linked polyethylene bearing in the hip[A]. In: D' Antonio JA, Dietrich M eds. Bioceramics and Alternative Bearings in Joint Arthroplasty-10th Biolox Symposiun[M]. 2005,21-24
  • 6Zichner L,Lindenfeld T. In-vivo wear of the slide combiinations ceramics polyethylene as opposed to metal-polyethylene. Orthopade, 1997; 26(2):129-134
  • 7Weber BG, Fiechter T. Polyethylene wear and late loosening of a total prosthesis of the hip joint. New perspectives for metal/metal pairing of the capsule and head. Orthopade, 1989; 18(5): 370-376
  • 8Oonishi H, Wakitani S, Murata N, et al. Oinical experience with ceramics in total hip replacement. Clin Orthop, 2000; 379:77-84
  • 9Clarke IC, Gustafson A. Clinical and hip simulator comparisons of eramic-on-polyethylene and metal-on-polyethylene wear, Clin Orthop, 2000, 379;34-40
  • 10Zichner LP, Willert HG. Comparison of alumina-polyethylene and metal -polyethylene in clinical trials. Clin Orthop, 1992; 282:86-94

共引文献24

同被引文献46

  • 1冯建民.全髋关节置换假体承重面的选择[J].中华临床医师杂志(电子版),2011,5(21):6204-6207. 被引量:4
  • 2Harris WH. Traumatic arthritis of the hip after dislocation and ace- tabular fractures:treatment by mold arthroplasty. An end-resuh study using a new method of result evaluation[ J]. J Bone Joint Sarg Am, 1969,51 (4) :737 -755.
  • 3Ladon D, Doherty A, Newson R, et al. Changes in metal levels and chromosome aberrations in the peripheral blood of patients after met- M-on-metal hip arthroplasty [ J ]. J Arthroplasty, 2004, 19 ( 8 Suppl 3 ) :78 - 83.
  • 4Jameson SS, Lees D, James P, et al. Drwer rates of dislocation with increased femoral head size after primary total hip replacement: a five-year analysis of NHS patients in England[ J]. J Bone Joint Surg Br,2011,93 (7) :876 -880.
  • 5Stanat SJ, Capozzi JD. Squeaking in third-and fourth-generation ce- ramic-on-ceramic total hip arthroplasty:meta-analysis and systematic review [ J ]. J Arthroplasty, 2012,27 ( 3 ) : 445 - 453.
  • 6Hamilton WG, McAuley JP, Dennis DA, et al. THA with Delta ce- ramic on ceramic:resuhs of a multicenter investigational device ex- emption trial [ J ]. C lin Orthop Relat Res,2010,468 (2) :358 -366.
  • 7肖鹏,吴学建,刘宏建.人工关节置换术后隐性失血的相关分析[J].中国组织工程研究与临床康复,2008,12(4):635-638. 被引量:35
  • 8陈云苏,张先龙,邵俊杰,沈灏,王琦.陶瓷-陶瓷全髋关节置换术中困难及对策[J].国际骨科学杂志,2009,30(2):86-88. 被引量:7
  • 9郑明,林凤飞,林朝晖,宋卫,林清坚.不同材料假体人工全髋关节置换效果的临床观察[J].中国矫形外科杂志,2009,17(13):977-979. 被引量:18
  • 10杜斌.金属对金属大直径股骨头全髋关节置换术[J].中国组织工程研究与临床康复,2009,13(52):10396-10396. 被引量:3