摘要 目的:探讨64排螺旋CT定位下眼球内磁性异物摘出的临床效果。方法:对48例48眼眼球内磁性异物患者进行回顾性分析。其中32例巩膜探查摘出异物后,24例再行白内障超声乳化并人工晶状体植入术,8例行玻璃体切割,摘出异物的同时清除玻璃体积血或积脓。结果:一期异物全部摘出。术后视力全部不同程度地提高。结论:64排螺旋CT定位下眼球内磁性异物摘出是眼球内异物摘出的一种有效方法。 AIM:To evaluate the clinical effect of 64 spiral CT localization method in extracting magnetic intraocular foreign body.METHODS:Fourty-eight cases(48 eyes) with 64 spiral CT intraocular foreign bodies were analyzed retrospectively,including 32 cases of intraocular foreign body extraction,of which 24 cases were performed phacoemulsification and intraocular lens implantation,and 8 cases of vitrectomy for extraction of foreign bodies and removal of blood or vitreous empyema at the same time.RESULTS:Magnetic intraocular foreign bodies were extracted by 64 spiral CT localization method completely in all eyes.The postoperative visual acuity of the patients all had varing degrees of rise.CONCLUSION:64 spiral CT localization method is a smiple and effective method for extracting magnetic intraocular foreign body.
出处 《国际眼科杂志》 CAS 2012年第4期786-787,共2页 International Eye Science
关键词 球内异物 磁性异物 摘出 intraocular foreign body magnetic foreign body extraction