摘要
利用房间热平衡法对冷风机的性能进行了实验研究 ,确定了冷风机制冷量和传热系数的变化规律 。
The authors have carried out quite a few experimental studies on the performance of air cooler, and have got the changing rule of cooling capacity and heat transfer coefficient, based on experimental results, the authors also got the calculating formula of convection coefficient on air side of air cooler
出处
《哈尔滨建筑大学学报》
EI
2000年第1期55-59,共5页
Journal of Harbin University of Civil Engineering and Architecture
关键词
冷风机
房间热平衡法
制冷量
传热系数
air cooler
room heat balance method
cooling capacity