期刊文献+

Measurements,characteristics,and origin of new electromagnetic interference on magnetocardiographic measurements 被引量:1

Measurements,characteristics,and origin of new electromagnetic interference on magnetocardiographic measurements
原文传递
导出
摘要 In order to eliminate the influence of the large-amplitude magnetic field noise that has complicated magnetocardio- graphic studies since October 2009, we have performed high-accuracy measurement of the environmental magnetic field noise in the vicinity of Beijing Subway Line 4 using a three-component height Tc radio frequency (rf) superconducting quantum interference device (SQUID). By analysing the spatial form and other characteristics of the time and the fre- quency domains and by calculating the circumferential magnetic field distribution based on a duel-end feeding system model, we reach the following conclusions: (i) the main source of magnetic field noise is the magnetic field generated by thel subway trains, and (ii) the magnetic field interference results mainly from the imbalance between traction current and return rail current that is caused by the leakage current. In order to eliminate the influence of the large-amplitude magnetic field noise that has complicated magnetocardio- graphic studies since October 2009, we have performed high-accuracy measurement of the environmental magnetic field noise in the vicinity of Beijing Subway Line 4 using a three-component height Tc radio frequency (rf) superconducting quantum interference device (SQUID). By analysing the spatial form and other characteristics of the time and the fre- quency domains and by calculating the circumferential magnetic field distribution based on a duel-end feeding system model, we reach the following conclusions: (i) the main source of magnetic field noise is the magnetic field generated by thel subway trains, and (ii) the magnetic field interference results mainly from the imbalance between traction current and return rail current that is caused by the leakage current.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第4期185-192,共8页 中国物理B(英文版)
基金 supported by the State Key Development Program for Basic Research of China (Grant Nos. 2006CB601007 and 2011CBA00106) the National Natural Science Foundation of China (Grant No. 10674006) the National High Technology Research and Development Program of China (Grant Nos. 2007AA03Z238 and 2007AA03Z213)
关键词 electromagnetic interference leakage current subways MAGNETOCARDIOGRAPHY electromagnetic interference, leakage current, subways, magnetocardiography
  • 相关文献

参考文献12

  • 1Zhu X M, Ren Y F, Yu H W, Zhao S P, Chen G H, Zhang L H and Yang Q S 2006 Chin. Phys. 15 100.
  • 2Nakaya Y and Mori H 1992 Clin. Phys. Physio. Meas. 13 191.
  • 3Cohen D, Edelsack E A and Zimraerman J E 1970 AppL Phys. Lett, 16 278.
  • 4Wang Q, Ma P, Lu H, Tang X Z, Hua N and Tang F K 2009 Chin. Phys. B 18 5566.
  • 5Wang H W, Kong X Y, Ren Y F, Yu H W, Ding H S, Zhao S P, Chen G H, Zhou Y L, Zhang L H, He Y S and Yang Q S 2004 Chin. Phys. 13 19.
  • 6Drung D 1955 IEEE Trans. Appl. Supercond. 5 2112.
  • 7Wakai R T, Wang M and Martin C B 1994 Am. J. Obstet. Gynecol. 170 770.
  • 8Jeng J T, Horng H E and Yang H C 2002 Physica C 368 105.
  • 9bi Z, Chen G H, Zhang L H, Yang Q S and Feng J 2006 Chin. Phys. 15 310.
  • 10Zhang M J, Lang P L, Peng Z H, Chen Y F, Chen K and Zheng D N 2006 Chin. Phys. 15 1903.

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部