摘要 采用直读光谱分析法测定高锰钢中锰含量,建立分析方法,并对锰测定值的不确定度分项进行了评估。结果表明,影响测量结果的主要不确定度分量为:校准曲线的不确定度、标样定值的不确定度、标准样品测量过程所产生的不确定度及样品测量过程随机性的不确定度,控制影响不确定度的主要因素,可以减少测量不确定度,保证分析结果的准确性,该方法也适合高锰钢中其他元素的评定。 The method for the determination of Mn in high manganese steel by photoelectric direct reading spectrometry was established,and the uncertainty in the determination of Mn was evaluated.The results showed that the working curve,standard value and randomicity of analysis process for standard and measured samples had a great influence on the determination.Therefore,the control on the above key factors can effectively reduce the uncertainty and ensure the analytical results more accurate.The method also suits for the determination of other elements in high manganese steel.
作者 孙红英
出处 《光谱实验室》 CAS CSCD 2012年第2期992-995,共4页 Chinese Journal of Spectroscopy Laboratory
关键词 光电直读光谱 不确定度 高锰钢 Photoelectric Direct Reading Spectrometry Uncertainty High Manganese Steel Manganese
  • 相关文献

参考文献3

  • 1北京矿冶研究总院分析室编.矿石及有色金属分析手册[M].北京:冶金工业出版社,2007.98-100.
  • 2中华人民共和国国家计量技术规范.测量不确定度评定与表示[S].JJF1059-1999.北京:中国计量出版社,1999.6-27.
  • 3原怀保,李月红.发射光谱分析法测量不确定度的评定与应用[J].光谱实验室,2007,24(3):396-399. 被引量:14

二级参考文献8

  • 1国家质量监督检验检疫总局.潮量不确定度的评定与表示[S]JJF1059-1999.北京:中国标准出版社,1999.1-7.
  • 2国家质量监督检验检疫总局.铝及铝合金光电发射光谱分析方法[S].GB/T7999-2000.北京:中国标准出版社,2000.
  • 3国家发展与改革委员会.阴极铜直读光谱分析方法[S].YS/T464-2003.北京:中国标准出版社,2003.
  • 4国家发展与改革委员会.铜及铜舍金光电直读光谱分析方法[S].YS/T482-2005.北京:中国标准出版社,2005.
  • 5国家发展与改革委员会.铜及铜合金X射线荧光光谱分析方法[S].YS/T483-2005.北京:中国标准出版社,2005.
  • 6国家质量监督检验检疫总局.标准样品工作导则(9)[S].GB/T15000.9-2004.北京:中国标准出版社,2004.1-4,
  • 7国家质最监督检验检疫总局.标准样品工作导则(4)[S].GB/T15000.4-2003.北京:中国标准出版社,2003.1-5.
  • 8国家质量监督检验检疫总局.标准样品工作导则(8)[S].GB/T15000.8-2003.北京:中国标准出版社,2003.1-5.