白内障超声乳化并人工晶状体植入术后眼对比敏感度与眩光对比敏感度比较 被引量:1

Comparison of contrast sensitivity and glare contrast sensitivity after phacoemulsification and intraocular lens implantation surgery
原文传递
导出
摘要 目的观察白内障超声乳化并人工晶状体植入术后眼对比敏感度(cs)与眩光对比敏感度(GS)之间的关系,探讨改善白内障术后视觉质量的途径。方法临床病例对照研究。对2010年4-11月在重庆麦格眼科医院就诊患者采用CSV-1000E对比敏感度测试仪检测白内障超声乳化人工晶状体植入术后129例129只眼的cs和GS,对术后人工晶状体眼的cs值与GS值进行非参数检验分析。结果在3、6、9、12e/d空间频率,cs值分别为1.66±0.22、1.79±0.31、1.52±0.27、1.13±0.27,GS值分别为1.60±0.21、1.74±0.29、1.44±0.28、1.04±0.33,检验z值分别为-4.90、-4.11、-5.45、-3.72,人丁晶状体眼的Gs值明显低于cs值,差异有统计学意义(P〈0.01)。结论白内障超声乳化并人工晶状体植入术后眼cs受眩光影响较大,GS明显下降。 Objective To observe the relationship between contrast sensitivity (CS) and glare contrast sensitivity (GS) after phacoemulsification and intraocular lens implantation surgery, and to explore the way of improving the postoperative visual quality. Methods By CSV - 1000E contrast sensitivity tester, contrast sensitivity (CS) and glare contrast sensitivity (GS) of 129 pseudophakic eyes after phacoemulsification and intraocular lens implantation surgery were detected, and the CS values and GS values were analyzed by non-parameter test. Results At 3, 6, 9, and 12c/d spatial frequencies, CS values were for 1.66±0.22, 1.79±0.31, 1.52±0.27, 1.13±0.27; GS values were for 1.60±0.21, 1.74±0.29, 1.44±0.28, 1.04±0.33; inspection Z values were for-4.90, -4.11, -5.45, -3.72. The GS values of pseudophakic eye were obviously lower than CS values with a statistically significant difference (P 〈0.01). Conclusions The CS values of postoperative pseudophakic eye are greatly influenced by the glare, and the GS values obviously decrease.
出处 《中国实用眼科杂志》 CSCD 北大核心 2012年第3期244-246,共3页 Chinese Journal of Practical Ophthalmology
关键词 超声乳化 人工晶状体眼 对比敏感度 眩光对比敏感度 Phacoemulsification Pseudophakic eye Contrast sensitivity Glare contrast sensitivity
  • 相关文献

参考文献9

  • 1Kuroda T, Fujikado T, Maeda N, et al. Wavefront analysis in eyes with nuclear or cortical cataract [J]. Am J Ophthalmol, 2002,134:1-9.
  • 2Owsley C. Contrast sensitivity[J]. Ophthalmol Clin North Ann, 2003,16: 171-177.
  • 3雄里译.生理光学[M].上海:科学技术出版社,1987:40-81.
  • 4Seiler T,Kaemmerer M,Mierdel P,et al. Ocular optical aberra- tions after photorefractive keratectomy for myopia and myopia astigmatism[ J ]. Arch Ophthalmol, 2000, 118 : 17-21.
  • 5Kasper T, Buhren J, Kohen T. Visual performance of aspherical and spherical intraoeular lens: intraindividual comparison of vi- sual acuity, contrast sensitivity, and higer order aberrations[J].J Cataract Refract Surg,2006,32: 2022-2029.
  • 6Chmitz S, Dick HB, Krummenauer F, et al. Contrast sensitivity and glare disability by halogen light after monofocal and multi- focal lens implantation [J]. Br J Ophthahnol, 2000, 84 (10): 1109-1112.
  • 7Frost NA,Sparrow JM. Use of vision tests in clinical decision making about cataract surgery: results of a national survey[J]. Can J Ophthalmol,2000,874(4) : 432-433.
  • 8Superstein R,Boyaner D,Overbury O. Functional complaints, visual acuity, spatial contrast sensitivity, and glare disability in preoperative and postoperative cataract patient [J]. J Calaract Refract Surg, 1999,25(4): 575-578.
  • 9Coupland SG, Kirkham TH. Improved contrast sensitivity with antireflective coated lenses in the presence of glare[J]. Can J Oohthalmol, 1984,53: 311-314.

共引文献1

同被引文献11

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部