摘要
目的:建立一种可行的精子浓度检测的室内质控方法。方法:设定20×106和80×106两种浓度的冷冻精液作为高、低值室内质控品(IQC),QC-BEADSTM质控珠(以下简称质控珠)作为对照。采用双盲法,4名技术员分别通过计算机辅助精液分析(CASA)对上述假定的室内质控品及质控珠进行精子浓度的测定,绘制出各自的质控图(Xbar图和Sbar图),连续检测1个月,计算出相应的高、低浓度值批内及批间变异系数(CV%),并进行比较。结果:①假定室内质控品高、低值批内变异系数分别CV3.5%,CV2.4%;批间分别为CV10.2%、CV9.6%。质控珠高、低值批内分别为CV5.1%,CV7.1%,批间分别CV7.1%,CV8.2%。两组高、低值的批内变异均<10%,批间变异均<15%,符合(Levey-Jennings)L-J质量控制原则,均能达到室内质控目的。②两组间高、低值的批内变异系数及批间变异系数无显著性差异(P>0.05),提示假定质控品可代替质控珠行实验室内部质量控制。结论:我们建立的精子浓度测定的室内质控方法是简单、易行、可靠。
Objective : To establish a method for internal quality control (IQC) of sperm concentration test in the laboratory. Methods: We set the concentrations of frozen semen at 20 ×10^6 and 80 ×10^6 as low and high concentrations of putative IQC products, with QC-BEADSTM quality control beads ( QCBs ) as the control. Using the double-blind method, four technicians determined the sperm concentrations of the IQC products and QCBs by computer-assisted sperm analysis, and drew a quality control chart ( Xbar chart and Sbar chart) for each product. Through a month of continuous detection, we calculated and compared the intra- and inter-batch co- efficients of variation ( CV% ) of the quality control products of high and low concentrations. Results : The intra-batch coefficients of variation of the assumed IQC products of high and low concentrations were CV3.5% and CV2.4%, and their inter-batch coefficients of variation were CVI0.2% and CV9.6%. The intra-batch coefficients of variation of the QCBs of high and low concentrations were CV5. 1% and CV7.1%, and their inter-batch coefficients of variation were CV7.1% and CV8%. The intra-batch coefficients of variation of both IQC products and QCBs of high and low concentrations were 〈 10% , and their inter-batch coefficients of variation were 〈 15%, which conformed to Levey-Jennings quality control principles and achieved IQC purposes. No significant differences were found in either intra- or inter-batch coefficients of variation between the IQC products and QCBs of high and low concentrations ( P 〉 0.05 ), indicating that assumed IQC products can replace QCBs for internal quality control in the laboratory. Conclusion: The IQC method we established for determining sperm concentration is simple, feasible and reliable. Natl J Androl, 2012, 18 (3) : 233 -238
出处
《中华男科学杂志》
CAS
CSCD
2012年第3期235-238,共4页
National Journal of Andrology
关键词
精液分析
精子浓度
质量控制
semen analysis
sperm concentration
quality control