摘要
对可乐废水采用总程平衡治理技术,经调查、试验与计算,对废水实行动态的分流.将占总水量不足2% 的浓废水进行厌氧处理,去除占COD总量70% 以上的污染物,使好氧处理负荷降低.根据费用计算中所作假设,在其它条件不变的情况下,总程平衡治理工艺吨水处理能耗可比常规好氧治理工艺节省48% .
The Coca Cola beverage wastewater was treated with the assembly balancing wastewater treatment technique.After investigation of the water quality and water amount,test of feasibility and analysis of technique and economy,the wastewater discharge was separated dynamically on time and space.The high concentration wastewater,that is less than 2% of the total wastewater quantity,was treated with anaerobic technique.It will remove pollutant that is more than 70% of the total pollutant,and reduce the load of aerobic treatment.According to suppose of cost analysis,after adopting the assembly balancing wastewater treatment technique,the energy cost will be lower 48% than that of conventional aerobic process.
出处
《环境科学》
EI
CAS
CSCD
北大核心
2000年第1期98-101,共4页
Environmental Science
基金
北京市科委研究项目
关键词
饮料
清洁生产
总程平衡
废水处理
beverage wastewater,assembly balancing,dual system,clean production.