以某批次的制冷效果不佳的厦门金旅的6105CNG公交车为例,分析顶置天然气瓶公交车空调了制冷效果不佳的原因,并根据实际情况提出改进意见,测试对比了改进前后的效果,为同行提供参考.
This article takes the XML6105 CNG bus of Golden Dragon as an example to analyze the reason of ineffective air conditioning of the bus with overhead gas bottle. It gives some suggestion based on the actual situation, and compare the before and after improvement effect by testing to provide a reference for the person in this profession.