期刊文献+

基于干电极的头带式射频无线脑-机接口系统 被引量:4

A Dry electrode based headband radio frequency wireless brain-machine interface system
在线阅读 下载PDF
导出
摘要 研发了一种采用干电极的脑-机接口系统,此系统克服了现有脑机接口用脑电信号采集及信号处理系统笨重而不便于携带的缺点。此系统采用半导体微加工工艺制作的“干”电极作为采集脑电信号的电极,佩戴方便且能长时间使用。整个便携式脑机接口系统在脑电信号采集、处理和传输三个方面都采用了利于便携的设计,信号处理采用专用的集成电路,信号的采集和处理端与信号接收端采用射频芯片收发数据。整个系统的重量只有39g。该脑-机接口系统以人体的专注程度作为控制外部设备的控制信号,经过训练的受试者可以通过脑电信号实现对机器的控制。 A new portable wireless brain-machine interface (BMI) system was designed and fabricated using the techinque of dry electrode. The dry electrode was used in this system to record Electroencephalography ( EEG), and it was fabricated using the standard micromachining techniques so it is easy to wear. The system was composed of the three parts of signal recording, processing and transmission. Electroencephalography was recorded by the dry electrode, and was amplified, processed by using the application specific integrate circuit (ASIC), and the processed signal waw transmitted to the receiver by the wireless module. The EEG recording and processing module weighs 39g only. The system can be used to obtain the attention amplitude of the testees, and those trained testees could have the ability to control the machine through the EEG signal.
出处 《高技术通讯》 CAS CSCD 北大核心 2012年第2期211-216,共6页 Chinese High Technology Letters
基金 863计划(2007AA032427),973计划(2011CB933203&2011CB933102)和国家自然科学基金(60776024,60877035,90820002,61078074)资助项目.
关键词 脑-机接口(BMI) 干电极 脑电(EEG) 便携 brain-machine interface ( BMI), dry electrode, electroencephalography ( EEG), portable
  • 相关文献

参考文献18

  • 1Parag G P, Turner D A. The development of brain-machine interface neuroprosthetic devices. Development of BM! Neuroprosthetic Devices, 2008, 5 (1 ) : 137 -146.
  • 2Lebedev M A, Nicolelis MAL. Brain-machine interface: The challenge of neuroethics. TRENDS in Neurosciences, 2006, 29 ( 9) : 267 -269.
  • 3Waldert S, Pi stohl T, Braun C, et al. A review on directional information in neural signals for brain-machine interfaces. Journal of Physiology Paris, 2009, 130: 244- 254.
  • 4Gruetzmann A, Hansen S, Muller J. Novel dry electrodes for ECG monitoring. Physiological Measurement, 2007, 28(11) :1375-1390.
  • 5Henry S, McAllister D, Allen M, et al. Micromachined needles for the transdennal delivery of drugs. In: Proceedings of the IEEE 11 th Annual International Workshop on Micro-Electro Mechanical Systems, Heidelberg, Germany, 1998, 494498.
  • 6Ruffini G, Dunne S, Farres E, et al. A dry electrophysiology electrode using CNT arrays. Sensors and Actuators A, 2006, 132(1) :3441.
  • 7Yu L M, Tay F, Guo D G, et al. A microfabricated electrode with hollow micro needles for ECG measurement. Sensors and Actuators A, Physical, 2009, 151 (1 ) : 17 -22.
  • 8Gondran C, Siebert E, Fabry P, et al. Non-polarisable dry electrode based on NASICON ceramic. Medical and Biological Engineering and Computing, 1995, 33 (3) : 452457.
  • 9Gondran C H, Siebert E, Fabry P. NASICON based electrodes for bioelectric signal measurements. Proceeding of the Annual International Conference of the IEEE, 1992, 14(6) :2706-2708.
  • 10Ruffini G, Dunne S, Farres E, et al. A dry electrophysiology electrode using CNT arrays. Sensors and Actuators A, Physical, 2006, 132 :3441.

二级参考文献39

  • 1Birbaumer N. Breaking the silence: Brain-computer interfaces for communication and motor control [J]. Psychophysiology, 2006, 43(6): 517- 532.
  • 2Wolpaw J R, Birbaumer N, McFarland D J, et al. Brain-computer interfaces for communication and control [J]. Clinical Neurophysiology, 2002, 113(6): 767- 791.
  • 3Sellers E W, Krusienski D J, McFarland D J, et al. A P300 event-related potential brain-computer interface (BCI): The effects of matrix size and inter stimulus interval on performance [J]. Biological Psychology, 2006, 73(3): 242- 252.
  • 4Donchin L A. Talking off the top of your head: Toward a mental prothesis utilizing event-related brain potentials [J]. Electroenceph. Clin. Neurophysiol, 1988, 701 510- 523.
  • 5Blankertz B, Muller ,K R, Curio G, :et al. The BCI competition 2003- Progress and perspectives in detection and discrimination of EEG single trials [J]. IEEE Transactions on Biomedical Engineering, 2004, 51(6) : 1044 - 1051.
  • 6Blankertz B, Muller K R, Krusienski D J, et al. The BCI competition Ⅲ: Validating alternative approaches to actual BCI problems [J]. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2006, 14(2): 153-159.
  • 7Sellers E W, Donchin E. A P300-based brain-computer interface: Initial tests by ALS patients [J]. Clinical Neurophysiology, 2006, 117(3) : 538 - 548.
  • 8Piccione F, Giorgi F, Tonin P, et al. P300-based brain computer interface: Reliability and performance in healthy and paralysed participants [J]. Clinical Neurophysiology, 2006, 117(3): 531-537.
  • 9Polich J, Ellerson P C, Cohen J. P300, stimulus intensity, modality, and probability [J]. International Journal of Psychophysiology, 1996, 23(1 - 2) : 55 - 62.
  • 10Burges C J C. A tutorial on Support Vector Machines for pattern recognition [J]. Data Mining and Knowledge Discovery, 1998, 2(.2) : 121 - 167.

共引文献26

同被引文献66

引证文献4

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部