摘要
通过对HG-2035/26.15-YM3型超临界机组锅炉的分析研究,对锅炉运行中存在的再热汽温偏低、炉膛烟气偏差大问题等进行了详细分析,并提出了可行的针对性建议,为机组长期安全经济运行提供了指导依据。
In this paper, combustion adjustment test of 600MW boiler in Jingdezhen power plant was introduced. Based on the test, we get the optimal running parameters and methods. Some problems just like low reheat temperature and the deferent furnace outlet temperature etc. was analyzed. In the same time, some advice was also provided for the safe and economic running.
出处
《江西电力》
2011年第6期44-48,共5页
Jiangxi Electric Power
关键词
超临界
直流锅炉
燃烧调整
supercdtical
once through boiler, combustion adjustment