摘要
用火焰原子吸收法测定涂料中可溶性铅、铬含量,在室温、盐酸酸度、搅拌速度等条件恒定的情况下,考察了漆膜厚度、粉碎颗粒大小对实验结果的影响。试验表明测试结果受漆膜厚度、粉碎颗粒大小的影响很大。
Using flame atomic absorption spectrometry for the determination of soluble lead and chromium content in coatings, investigated the effects of the fihn thickness and crushing particle size on the experimental results at the same room temperature, hydrochloric acidity, stirring speed. It showed that the testing results were. greatly affected by the film thickness and crushing particle size.
出处
《上海化工》
CAS
2012年第2期17-19,共3页
Shanghai Chemical Industry
关键词
火焰原子吸收法
可溶性
铅含量测定
铬含量测定
涂料
Flame atomic absorption spectrometry
Soluble
Lead content
Chromium content
Coatings