摘要 输电工程中输电塔主材通常采用双角钢十字组合截面的方式,其受力情况非常复杂。通过对12组双角钢十字组合截面偏心压杆的足尺试验和有限元分析,考察了单节间和双节间压杆的受力性能和破坏模式,并利用多参数有限元分析了宽厚比、长细比以及填板数量和布置方式等主要参数对压杆承载力的影响,提出了其组合截面承载力计算方法,并与试验和有限元所得的结果进行了比较。结果表明,基于偏心的双角钢十字组合截面压杆建议的计算方法合理有效,具有较好的适用性。 The members with combined angle iron cross-section are widely used in electric transmission towers and its behavior is complex.Twelve groups full-scale tests and the finite element analysis were conducted to study the compressive behavior of eccentric members with combined angle iron cross-section,and the buckling failure mode and behavior of test specimens of single inter-node and double inter-node were observed.The effects of width-thickness ratio,slenderness ratio and the number and distribution of filled plate on the ultimate strength were analyzed and the design method of members with combined angle iron cross-section was put forward and compared with the result of experimentation and FEM.The results showed that the method has theoretical and practical significance for design.