期刊文献+

水解酸化/接触氧化/曝气生物滤池处理工业园废水工程实例 被引量:9

Case study on the treatment of wastewater in an industrial park by hydrolytic acidification-contacting oxidation-biological aerated filter process
在线阅读 下载PDF
导出
摘要 采用"水解酸化—接触氧化—曝气生物滤池"工艺处理由印染废水和生活污水组成的工业园废水,其CODCr从800 mg/L左右降到60 mg/L以下,BOD5从250 mg/L左右降到20 mg/L以下,去除率均达到了92%以上,出水水质达到《城镇污水处理厂污染物排放标准》(GB 18918—2002)中一级标准的B标准。 The wastewater in an industrial park can be treated by hydrolytic acidification-contacting oxidation- biological aerated filter(BAF) process. The wastewater mainly consists of printing & dyeing wastewater and domestic sewage. Through the operation of this process ,the CODCr of effluent can fall from about 800 mg/L of influent to below 60 mg/L, and BOD5 of effluent can fall from about 250 mg/L of influent to below 20 mg/L. Both of the removal rates can reach more than 92%. The effluent water quality reaches Standard B of the first order in Pollutants Emission Standard of Urban Wastewater Treatment Plants (GB 18918--2002).
出处 《工业水处理》 CAS CSCD 北大核心 2012年第2期85-87,共3页 Industrial Water Treatment
基金 "水体污染控制与治理"国家重大科技专项(2008ZX07211-005-004)
关键词 印染废水 水解酸化 接触氧化 曝气生物滤池 printing & dyeing wastewater hydrolytic acidification contacting oxidation biological aerated filter