期刊文献+

超滤膜处理净水厂沉淀池出水的中试研究 被引量:2

Treatment of Effluent from Sedimentation Tank of Waterworks by Ultrafiltration Membrane
原文传递
导出
摘要 采用中试规模的内压式超滤膜系统处理水厂沉淀池出水,考察超滤膜系统长期运行的出水水质情况。结果表明,超滤膜系统在处理不同水质期沉淀池出水时具有较高的除浊率,平均除浊率达到93.4%,且99.4%的出水浊度<0.1 NTU,去除效果明显优于同期传统的滤池工艺。超滤膜系统对沉淀池出水中有机物的去除效果有限,对CODMn和UV254的平均去除率分别为17.2%和8.2%,出水CODMn≤2.0 mg/L的保证率在98%以上,膜出水CODMn浓度受进水水质和运行条件的影响不大。膜进水中以小分子质量有机物为主,在MW<1 ku区间内的DOC和UV254占到整体有机物含量的57.3%和53.5%。超滤膜系统对微生物的去除效果良好,膜出水水质大部分时间无需经过消毒就能保证卫生要求,可降低后续消毒的加氯量,从而减少消毒副产物的生成量。 A pilot-scale internal pressure uhrafiltration (UF) membrane system was used to treat effluent from sedimentation tank in a waterworks and the quality of produced water from UF membrane system was investigated for a long time. The results demonstrated that a high removal rate of turbidity was achieved in different water quality periods, with an average removal rate of 93.4%. The guarantee rate of turbidity below 0.1 NTU was 99.4%. The removal efficiency of UF membrane system was significantly better than that of conventional filter process. The removal efficiency of organic matters in the effluent from sedimentation tank by UF membrane system was limited. The average removal rates of CODM, and UV254 were 17.2% and 8.2% , respectively. The guarantee rate of CODMn≤ 2 mg/L was above 98%. The CODM,' concentration in membrane effluent was little influenced by the influent quality and the operation condition. Organics with low molecular weight were dominant in membrane influent. DOC and UV:54 with MW of less than 1 ku accounted for 57.3% and 53.5% of the total organics. Microorganisms could be effectively removed by UF membrane system, and the membrane effluent quality could meet the hygiene requirements without disinfection, which reduced the chlorine dosage for subsequent disinfection and the formation of disinfection byproducts.
出处 《中国给水排水》 CAS CSCD 北大核心 2012年第5期40-43,共4页 China Water & Wastewater
关键词 饮用水处理 内压式超滤膜 浊度 微生物 分子质量分布 drinking water treatment internal pressure UF membrane turbidity microorganism molecular weight distribution
  • 相关文献

参考文献5

二级参考文献27

共引文献72

同被引文献28

  • 1范正虹,陈福泰,陈晓婷,黄霞,马启敏,朱列平.微滤/反渗透净化污水厂二级处理出水[J].中国给水排水,2005,21(6):44-46. 被引量:13
  • 2孙丽华,李星,吕谋,夏圣骥,李圭白.五种预处理方式对超滤膜处理松花江水的效能比较[J].给水排水,2007,33(5):133-136. 被引量:12
  • 3郝瑞霞,曹可心,邓亦文.三维荧光光谱法表征污水中溶解性有机污染物[J].分析试验室,2007,26(10):41-44. 被引量:52
  • 4Koyuncu I, Topacik D, Turan M, et al. Application of the membrane technology to control ammonia in surface wa- terl [J ]. Water Sci Technol: Water Supply,2001,1 ( 1 ) : 117 - 124.
  • 5Tomaszewska M, Mozia S. Removal of organic matter from water by PAC/UF system [ J ]. Water Res,2002,36 (16) :4137 -4143.
  • 6Peter-Varbanets M, Zurbragg C, Swartz C,et al. Decen- tralized systems for potable water and the potential of membrane technology [ J ]. Water Res,2009,43 (2) :245 - 265.
  • 7Peter-Varbanets M,Hammes F,Vital M,et al. Stabiliza- tion of flux during dead-end ultra-low pressure ultrafiltra- tion[ J]. Water Res,2010,44(12) :3607 - 3616.
  • 8Peter-Varbanets M, Margot J, Traber J, et al. Mecha- nisms of membrane fouling during ultra-low pressure ul- trafihration[ J ]. J Membr Sci, 2011,377 ( 1/2 ) : 42 - 53.
  • 9Ding A,Qu F,Liang H,et al. A novel integrated vertical membrane bioreactor (IVMBR) for removal of nitrogen from synthetic wastewater/domestic sewage [ J ]. Chem Eng J,2013,223:908 - 914.
  • 10Derlon N,Mimoso J,Klein T,et al. Presence of biofilms on ultrafiltration membrane surfaces increases the quality of permeate produced during ultra-low pressure gravity- driven membrane filtration [ J ]. Water Res, 2014,60 : 164 - 173.