摘要 针对变电站电压无功控制中,存在的变压器分接头和电容器组投切频繁以及电容器投切对系统电压造成一定的冲击问题,将静止同步补偿器(STATCOM)用于变电站电压/无功调节控制中,提出了离散设备优先动作,连续设备精细调节的控制策略,协调有载调压变压器分接头、电容器组与STATCOM之间的运行,在电压发生波动时,投入STATCOM实现对电压快速和平滑的调节;在正常运行时,STATCOM有足够的裕量。在修正后的IEEE-9系统中对提出的的控制策略进行仿真分析,结果表明,提出的协调控制策略能够有效地减少变压器分接头和电容器的投切次数,减小电容器投切时对系统电压造成的冲击。 For voltage and reactive power control of substation, presence of transformer taps and capacitor banks switching frequently have certain impact on the system voltage. The static synchronous compensator (STATCOM) is used in the voltage/reactive power control of substation, and it is proposed for discrete device priority action, continuous fine adjustment device control strategy to coordinate the running of transformer taps, capacitor banks and STATCOM. STATCOM is put into operation to get fast and smooth adjustment of voltage when the voltage fluctuates. STATCOM has enough margins in normal operation. In the modified IEEE-9 system for the proposed control strategy simulation analysis, results showed that the coordination control strategy can effectively reduce the switching times of the transformer and capacitor, decrease the impact of capacitor switching on system voltage.
出处 《电网与清洁能源》 2012年第1期54-59,共6页 Power System and Clean Energy
关键词 有载调压 电压调节 STATCOM 协调控制 on-load tap changing voltage regulation STATCOM coordination control
  • 相关文献

参考文献10

  • 1Lrvine R L, Busch A.W. Sequencing batch biological reactors- an overview [J]. Water Sci Tech .1997,35(1): 1-10
  • 2张玉珠,徐文忠,付红艳.结合灵敏度分析的变电站电压无功控制策略[J].电力系统保护与控制,2009,37(2):37-42. 被引量:21
  • 3Lazarova V, Manem J. Advances in biofilm aerobic reactors ensuring effective biofilm activity control [ J]. Water Sci Tech, 1994,29(10-11): 319-327
  • 4Sorensen P B, Agerback M L, Sorensen B L. Predicting cake filtration using specific flow rate [J]. Water Environ Res, 1995,67(5): 764-773
  • 5Sorensen B L, Keiding K, Lauritzen S L. A theoretical model for blinding in cake filtration [ J ]. Water Environ Res, 1996,69(2):168-173
  • 6Mojtaba Khederzadeh. Coordination control of STATCOM and ULTC of power transformers[C]. Universities Power Engineering Conference, 2007:613-618.
  • 7Sorensen P B , Christensen J R , Bruus J H. Effect of small scale solids migration in filter cake duringfiltration of wastewater solid suspensions [J]. Wat Environ Res, 1995,69 ( 1 ): 25-32
  • 8栗春,马晓军,姜齐荣,王仲鸿,修林成.用STATCOM改善系统电压调节特性的动模实验[J].中国电机工程学报,1999,19(9):46-49. 被引量:22
  • 9郭庆来,孙宏斌,张伯明,吴文传,王彬,李柱华,汤磊,王蓓,宁文元,郑燕涛,袁平.自动电压控制中连续变量与离散变量的协调方法 (一)变电站内协调电压控制[J].电力系统自动化,2008,32(8):39-42. 被引量:32
  • 10尉飞.STATCOM在电压/无功控制中协调应用的研究[D].西安:西安理工大学,2010.

二级参考文献23

共引文献73

同被引文献254

引证文献19

二级引证文献126

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部