燃煤电厂无旁路湿法烟气脱硫系统设备配置与选型 被引量:4

Configuration and type selection of equipments for wet FGD system without bypass in coal-fired power plants
在线阅读 下载PDF
导出
摘要 分析了简化脱硫系统配置,优化主要设备选型,增加防腐、防磨措施的可行性,论述了取消烟气旁路后保证脱硫装置可靠性的措施,供烟气脱硫系统设备配置与选型时参考。 The feasibility of simplifing the desulphurization system configuration,optimizing the main equipments selection and adding anticorrosion and anti-abrasion measures were analyzed.The measures for ensuring the reliability of desulphurization equipments after eliminating the flue gas bypass were expounded,which can be used as reference for FGD system in equipment configuration and selection.
出处 《华电技术》 CAS 2012年第2期75-76,80,共2页 HUADIAN TECHNOLOGY
关键词 湿法脱硫 烟气换热器 无旁路 烟塔合一 设备配置 选型 wet desulphurization gas-gas heater(GGH) without bypass cooling water in place of chimney combining tower equipment configuration type selection