期刊文献+

前列腺双极等离子汽化电切术对心脏起搏器工作的影响观察 被引量:7

Observe the efficacy of pacemaker in transurethral bipolar vaporization of prostate
原文传递
导出
摘要 目的:观察前列腺双极等离子汽化电切术对心脏起搏器工作的影响。方法:选取22例携带有心脏起搏器的前列腺增生患者行前列腺双极等离子气化电切术,术前行24h动态心电图检查,术中密切监护心电变化,术后24h心电监护,术后1周行24h动态心电图检查以了解起搏器的工作状态的变化。结果:术前术后起搏器工作状态未发生改变,术中心电图也未受到明显干扰,手术顺利完成,围手术期心功能稳定。结论:未发现前列腺双极等离子气化电切术对心脏起搏器的工作产生干扰,留置心脏起搏器并非是前列腺等离子双极汽化电切术的禁忌证。 Objective:Objective to observe the efficacy of pacemaker in transurethral bipolar vaporization of prostate. Method:Twenty-two patients of benign prostate hyperplasia with permanent pacemaker implantation were selected,To understand the working status of the change of the pacemaker rely on the results of the Dynamic Electro-cardiogram in preoperative.The electrocardiographic monitor in operation and after surgery 1 week review Dynamic Electro-cardiogram. Result:Pacemakers working state not changed before the operation and after surgery,Intraoperative electrocardiogram were not obvious interference,Operation successfully completed,Perioperative heart function stability. Conclusion:No interference to pacemaker was found in transurethral bipolar vaporization of prostate.The patients with permanent pacemaker implantation is not the contraindication of transurethral bipolar vaporization of prostate.
出处 《临床泌尿外科杂志》 2012年第2期146-147,共2页 Journal of Clinical Urology
关键词 前列腺双极等离子汽化电切 起搏器 前列腺增生 transurethral bipolar vaporization of prostate pacemaker benign prostate hyperplasia
  • 相关文献

参考文献5

二级参考文献22

  • 1刘晓健,胡晓晟.起搏器感知功能过度的几种表现形式[J].心电学杂志,2004,23(4):237-239. 被引量:6
  • 2季惠翔,张家华,宋波,金锡御.安置心脏永久性起搏器患者的经尿道前列腺电切治疗[J].中华男科学杂志,2005,11(7):530-531. 被引量:8
  • 3吴开俊.中国人前列腺增生症治疗现状与展望[J].中华泌尿外科杂志,1993,15:12-4.
  • 4STEIN B.The evaluation and treatment of BPH[J].Med Health R I,2002,85(5):153-155.
  • 5SOUQUES M.The influence of nonionizing electromagnetic fieldson imp lantable cardiac medical devices[J].Presse Med,2004,33 (22):1611-1615.
  • 6ROGUIN A,ZVIMAN MM,MEININGER GR,et al.Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe:in vitro and in vivo assessment of safety and functionatl[J].Circulation,2004,110(5):475-482.
  • 7SWEESY MW,HOLLAND JL,SMITH KW.Electromagnetic interference in cardiac rhythm management devices[J].AACN Ciin Issues,2004,15(3):391-403.
  • 8CETINKAYA M,OZTURK B,AKDEMIR O,et ai.A comparison of fluid absorption during transurethral resection and transurethral vaporization for benign prostatic hyperplasia[J].BJU Int,2000,86(7):820-823.
  • 9CHAMBERS A.Transurethral resection syndrome it does not have to be a mystery[J].AORN J,2002,75(1):156-164.2002:564.
  • 10Stein B. The evaluation and treatment of BPH, 2002 [ J ]. Med Health R I, 2002, 85(5) :153-155.

共引文献8

同被引文献67

引证文献7

二级引证文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部