期刊文献+

静脉血管超声定位检测仪的研制 被引量:2

The design of ultrasonic location for vein vessel
暂未订购
导出
摘要 本文介绍了我们所研制的超声波静脉血管定位检测仪。该仪器利用A超和连续多普勒技术,采用计算机控制及数字处理方法,可以确定静脉血管的位置及血流的大小,目前已完成仿真模型实验。该研究具有重要的临床应用价值。 This paper reports a location measurement instrument of vein vessel by ultrasound. The instrument is realized by comb- ing A-mode ultrasound with CW doppler technique and using computer controlling and digitalized processing, the instrument can locate the vein blood vessel quickly. The experiment of model simulation has been worked successfully. It has certain value in clinic.
出处 《中国医学物理学杂志》 CSCD 2000年第1期32-33,共2页 Chinese Journal of Medical Physics
关键词 超声波 单片计算机 定位检测 ultrasound singal -chip -microcomputer location measurement
  • 相关文献

参考文献4

  • 1万明习,等.医学超声--原理与技术[M].西安:西安交通大学出版社,1992.
  • 2王 静. 数字化超声波血流量测试系统的研制[D].西安:西安交通大学硕士论文,1992.
  • 3Douglas A. Christensen:Ultrasonic Bioinstrumenation[Z],John Wily andSons,Inc.New York,1983.
  • 4刘镇清.μPC1018C用于高频超声波信号放大[J].电子技术应用,1992,4.

共引文献1

同被引文献17

  • 1杨云燕,崔立刚,周艳艳,葛宝兰,王金锐.高频超声引导定位前臂浅静脉穿刺[J].中国微创外科杂志,2006,6(12):986-987. 被引量:4
  • 2黄雪霞,吕艳,马丽娅,李向真,潘东洪,陆桂妙.浅静脉留置针穿刺中双止血带双交叉结扎法的临床研究[J].护士进修杂志,2007,22(9):786-788. 被引量:20
  • 3Hind D, Calvert N, Me Williams R, et al. Ultrasonic locating devices for venous canulation: meta-analysis. BMJ, 2003, 327(7411) : 361.
  • 4Arai T, Yamashita M. Udio-Doppler guidance using a small- caliber Doppler probe for internal jugular venous puncture for central venous catheterization in infants and children.Paediatr Anaesth,2004,14 (9):744.
  • 5Schummer W, Schummer C, Niesen WD, et al. Doppler-guided cannulation of internal jugular vein, subclavian vein and innominate (brachiocephalic) vein: a case-control comparison in patients with reduced and normal intracranial compliance. Intensive Care Med, 2003, 29(9) : 1535.
  • 6Lefrant JY. Pulsed Doppler ultra-sonography guidance for catheterization of the subclavian vein: a randomized study. Anesthesiology, 1998,88(5):1195.
  • 7Schregel W.Ultrasonie guided cannulation of the axiUary vein in intensive care patients. Anaesthesist, 1994,43 (10) : 674.
  • 8Prabhu V, Mohanavelu K, Sundersheshu B S, et al.Vein identification and localization for automated intra-venous drug delivery system [ M]//Wireless Networksand Computational Intelligence. Heidelberg, German:Springer Berlin, 2012: 270 -281.
  • 9Kavitha R,Flower L. Localization of palm dorsal veinpattern using image processing for automated intra-ve-nous drug needle insertion [ J]. International Journal ofEngineering Science & Technology, 2011,3(6) : 4833-4838.
  • 10周雅,胡晓明,林俊清,等.一种多光谱三维静脉图像显示装置:中国,CN102813504A[ P]. 2012-12-12.