摘要
介绍了大唐哈尔滨第一热电厂烟塔塔壁防腐和塔壁表面局部脱落情况,通过外观质量检查和实验室检测,详细分析了烟塔塔壁表面局部脱落的原因,并提出了修复措施,指出了修复工艺过程应注意的问题。
Falling-off status of partial anti-corrosion coating and wall surface of the cooling tower in Datang Harbin No.1 Thermal Power Plant has been described.The causes of partial falling-off from the wall surface are analyzed in detail,for which specific repairing process and noteworthy items are raised based on visual inspection laboratory examination.
出处
《发电设备》
2011年第5期378-380,共3页
Power Equipment
关键词
排烟冷却塔
防腐层
表面脱落
修复
exhaust cooling tower
anti-corrosion layer
surface falling-off
repairing