期刊文献+

电导相关流量测井仪在气/水两相流下响应规律的实验研究 被引量:2

Experimental Analysis of Conductance Correlation Flowmeter in Gas-water Two-phase Flow
在线阅读 下载PDF
导出
摘要 通过对电导相关流量测井仪在多相流实验装置进行气/水两相流动态模拟实验,总结出电导相关流量测井仪在气/水两相流下的响应规律。实验数据分析认为,电导相关流量测井仪在气/水两相流下的适用范围为气流量不大于15m3/d。在气/水两相流条件下,电导相关流量测井仪在低流量和高流量时有不同的响应规律。气/水两相流总流量为20m3/d以上时,相关流量随气/水总流量的增加呈线性增加,受气流量的影响较小。总流量为20m3/d以下时,相关流量受气体滑脱速度影响较大。流量越低,滑脱越明显。在气/水两相与油/水两相下的对比实验表明,气/水两相流中总流量为20m3/d以上时的仪器常数与油/水两相的仪器常数非常接近。在同一总流量下,气/水两相流时测量的相关流速明显高于同流量时油/水的相关流速。 The experiment of conductance correlation flowmeter is carried out on the simulation multi-phase flow experiment facility under the condition of gas-water two-phase flow. The response regulations of the flowmeter in the gas-water two-phase flow are summarized. The analyses of experiment data show that the flowmenter' s working range in gas-water two-phase flow is the gas flowrate below 15 m3/d. The flowmeter has different response regulations at low flowrate and high flowrate. When the total flowrate of gas-water two-phase flow is above 20 m3/d and gas flowrate is below 15 m3/d, the correlation flowrate increases linearly with the increases of total gas-water flowrate. When the total flowrate is beIow 20 m3/d, the correlation flowrate is more sensitive to gas flowrate, and is largely affected by gas slippage. The lower the flowrate is, the more obvious the gas slippage is. When the total flowrate is above 20 m3/d, the tool coefficient in gas-water two-phase flow is almost equal to the tool coefficient in oil-water two-phase flow. The correlation velocity in gas-water two-phase flow is obviously higher than the correlation velocity in oil-water two-phase flow with the same flowrate.
出处 《测井技术》 CAS CSCD 北大核心 2011年第6期508-511,共4页 Well Logging Technology
基金 国家科技重大专项(课题编号:2008ZX05020)资助课题
关键词 生产测井 电导相关 流量计 流量 气/水两相流 相关流速 实验研究 prodnction logging, conductance correlation, flowmeter, flowrate, gas-water two-phase flow, correlation velocity, laboratory research
  • 相关文献

参考文献5

二级参考文献36

  • 1Beck M S, Plaskowski A. Cross Correlation Flowmeters-Their Design and Application [ M ]. Bristol: Adam Hilger, 1987.
  • 2Butterfield M H,Bryant G F, Dowing J. A New Method of Strip Speed Measurement Using Random Waveform Correlation [ J ].Trans Soc Instrum Tech, 1962,13 (2): 111-113.
  • 3Bentey B A, Dawson D G. Fluid Flow Measurement by Transit Time Analysis of Temperature Fluctuations [ J ]. Trans Soc Instrum Tech, 1966,18 ( 3 ): 183-192.
  • 4Beck M S,Drane J,Plaskowski A,Wainwright N. Particle Velocity and Mass Measurement in Pneumatic Conveyors [ J ]. Powder Technology, 1968,2:269-277.
  • 5Beck M S. Correlation in Instruments:Cross Correlation Flowmeter[J]. Phys E:Sci Instrum,1981,14:7-19.
  • 6Beck M S. Recent Developments and the Future of Cross Correlation Flowmeters[ A]. Proc Int Conf on Advances in Flow Measurement Techniques [ C ]. Warwick, UK, 1981.9-11.
  • 7Thorn R, Beck M S, Green R G. Non-intrusive Methods of Velocity Measurement in Pneumatic Conveying [ J ]. Phys E: Sci Instrum,1982,15:1131-1139.
  • 8Mehrdadi B,Kaghazchi B, Beck M S. Non-contacting Level Measurement of Irregular Surfaces Using Coded Ultrasound and Cross Correlation Analysis [ J ]. Phys E: Sci Instrum, 1982,15:367-372.
  • 9Braun H, Fug M, Schneider G. Theory and Apphcation of an Alternative Correlation Flowmeter [ J ]. Chem Eng Technol,1987,10:353-360.
  • 10Xu L A, Green R G, Beck M S. The Pulsed Ultrasonic Cross Correlation Flowmeter for Two-phase Flow Measurement [ J ].Phys E: Sci Instrum, 1988,21:406-414.

共引文献48

同被引文献19

  • 1梁佳娜,梁国伟,沈平平.双锥流量计实验研究与计算模拟[J].中国计量学院学报,2010,21(3):201-205. 被引量:7
  • 2Meng Z Z, Huang Z Y, Wang B L, et al. Air-water two-phase flow measurement using a Venturi meter and an electrical resist- ance tomography sensorEJ3. Flow Measurement and Instrumen- tation, 2010, 21(3): 268-276.
  • 3Huang Z Y, Xie D L, Zhang H J, et al. Gas-oil two-phase flow measurement using an ecectrical capacitance tomography system and a VenturimeterEJ3. Flow Measurement and Instrument, 2005, 16(2-3): 177-182.
  • 4Dong F, Hu J. Study of the gas-liquid two-phase flow measur- ing method based on the V-cone flow meterECJ. The 5th Inter- national Symposium on Measurement Techniques for Multi- phase Flows, Macao, China, 2006: 214-220.
  • 5JAMES R. Metering of steam-water two phase flow by sharp edged orificesl-J]. Proc Inst Meech, 1965, 180(23): 594-566.
  • 6MURDOCK J W. Two-phase flow through measurement with orifices[J]. Journal of Basic Engineering, 1962, 84 (4) : 419- 433.
  • 7LIN Z H. Two-phase flow measurement with sharp-edged ori- fices[J]. International Journal of Multiphase Flow, 1982, 8 (6) : 683-693.
  • 8方立德,张涛,徐英.基于狭缝文丘里管的气液两相流测量[J].传感技术学报,2008,21(8):1458-1465. 被引量:3
  • 9张立峰,王化祥.基于SVM及电容层析成像的两相流流型识别[J].仪器仪表学报,2009,30(4):812-816. 被引量:30
  • 10胡金海,刘兴斌,张玉辉,周家强,庄海军.用于井下油水两相流测量的新型流量计[J].测井技术,1999,23(4):292-294. 被引量:19