期刊文献+

基于8~14μm带宽的谱带发射率的研究 被引量:2

A Primary Study of 8~14 μm Band Emittance
在线阅读 下载PDF
导出
摘要 针对红外测量中常用的8~14μm的带宽,依据前人的实验结果,计算了两种材料的谱带发射率,并且通过简单的实验,测量了几种材料的谱带发射率。实验和计算结果表明:谱带发射率与温度之间存在着某种函数关系。对于常用的带通辐射测温仪和热像仪,如果测量对象为非灰体,仍然把发射率值看作是一个常数,将会导致较大的测量误差。初步研究表明,对于非金属和真空中的金属,谱带发射率与温度近似存在线性关系。利用拟合出的谱带发射率与温度的函数关系式,可以作为辐射测温仪和热像仪的修正,不仅简化了计算,而且能够提高其测量精度。 According to the previous experimental results,the band emittance of two materials were computed for 8~14 mm bandwidth in infrared measuring.The band emittance of several materials was surveyed by a simple experiment.The experiment and reckoning show that there is some kind of functional relation between band emittance and temperature.If the object measured is non-gray,and emissivity is regarded as a constant,acute measurement error will be generated for band pass radiation thermometer and thermal imaging system.The band emittance is nearly linear with the temperature for nonmetal and metal in vacuum by primary analysis.The fitted function equation can be used as the modification of band pass radiation thermometer and thermal imaging system,and the band emittance not only simplifies the calculation,but also improves the accuracy of measurement.
出处 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2012年第2期289-292,共4页 Spectroscopy and Spectral Analysis
基金 国家自然科学基金项目(60977063) 贵州省教育厅自然科学基金重点项目(2010089)资助
关键词 光谱发射率 谱带发射率 辐射测温计 多项式拟合 Spectral emissivity Band emittance Radiation thermometer Polynomial fitting
  • 相关文献

参考文献11

  • 1戴景民,宋扬,王宗伟.光谱发射率测量技术[J].红外与激光工程,2009,38(4):710-715. 被引量:32
  • 2Khan M A,Allemand C,Eager T W.Rev.Sci.Instrum.,1991,62(2): 392.
  • 3Del Compo L,Pérez-Sáez R B,Esquisabel X,et al.Rev.Sci.Instrum.,2006,77(11): 113111.
  • 4Modest M F.Radiative Heat Transfer.San Diego: Academic Press,2003,3: 61.
  • 5Staaf O,Ribbing C R,Andersson S K.Applied Optics,1996,35(1): 6120.
  • 6Bauer W,Moldenhauer A.Proc of SPIE,2004,5405: 13.
  • 7Yuan Z.Int.J.Thermophys.,2009,30(1): 220.
  • 8原遵东.辐射温度计的等效波长及其应用[J].仪器仪表学报,2009,30(2):374-379. 被引量:20
  • 9Bauer W,Rink M,Grafen W.9th International Symposium on Temperature and Thermal Measurements in Industry and Science,2004,2: 1307.
  • 10Del Compo L,Pérez-Sáez R B,Tello M J,et al.Int.J.Thermophys.,2006,27(4): 1160.

二级参考文献23

  • 1原遵东.黑体辐射源发射率对辐射测温准确度的影响及修正方法[J].计量学报,2007,28(z1):19-22. 被引量:22
  • 2原遵东,段宇宁,王铁军,邢波.发射率设定值不为1的辐射温度计的校准[J].计量技术,2007(5):43-46. 被引量:16
  • 3KOSTKOWSKI H J, LEE R D. Theory and methods of optical pyrometry [ A ]. Temperature: Its Measurement and Control in Science and Industry[ C ]. Reinhold Publishing Co. , New York, 1962,3:449-481.
  • 4FISHER J, BATTUELLO M, ADLI M, et al. Uncertainty budgets for realization of ITS-90 by radiation thermometry[ A]. Temperature: Its Measurement and Control in Science and Industry [ C ]. AIP, Melville, New York, 2003,7:631-638.
  • 5CHU Zai-xiang,SUN Yu-xing, CHEN Shou-ren. Material spectra emissivity measurement technique[J].Infrared Research ,1986, 5A:231-239.
  • 6CEZAIRLIYAN A,MCCLURE J,LAYLOR R. Thermophysical measurements on 90Ti-6Al-4V alloy above 1 450 K using a transinent technique [J].Journal of Research of the National Bureau of Standards, Section A, Physics and Chemistry, 1977,81 (3): 251-256.
  • 7RIGHINI F, ROBERTS R B, ROSSO A.Measutrment of thermophysical properties by a pulse-heating method: niobium in the range 1 000-2 500 K[J].International Journal of Thermophysics, 1985,6 (6): 681-693.
  • 8KASCHNITZ E, POTTLACHER G,JAEGER H. New microsecond pulse-heating system to investigate thermophysical properties of solid and liquid metals[J].International Journal of Thermophysies, 1992,13 (4): 699.
  • 9DAI J M, FAN Y, CHU Z X.Development of a Millisecond Pulse-Heating Apparatus[J].International Journal of Thermophysies, 2002,23 ( 5 ): 1401 - 1405.
  • 10DUNKLE R V. In Progress in International Research on Thermodynamics and Transport Properties Asme[M].1962: 100-106.

共引文献50