摘要
目的:寻求破解常见B超软故障之道。方法:以多个维修案例为依据,通过对常见B超软故障进行分类研究,分析软故障的个性和共性,提供维修方法。结果:故障排除,提高设备使用效率。结论:通过对B超软故障的细致分类研究,能更好的提供行之有效的排除方法,为以后的维护使用提供借鉴。
Objective:To find solutions for typical breakdowns in B-mode ultrasonograph. Methods:Based on analysis of different breakdowns in the machine, we put forward solutions. Results:The efficiency of the machine was improved after troubleshooting. Conclusion:Solutions can be obtained through careful analysis of the typical breakdowns in the machine.
出处
《中国医学装备》
2011年第12期114-116,共3页
China Medical Equipment
关键词
软故障
B超
维修
Breakdown
B-mode ultrasonograph
Repair