摘要
本文针对完全能量耦合精馏塔,基于Fenske-Underwood-Gilliland方程建立了完整的简捷设计方法,得到了各塔的实际理论板数、适宜的进料和侧线液相采出位置以及各塔回流比等参数。并在此基础上通过严格模拟,对完全热耦合精馏塔的中间组分分配比β、气相分割比Rv和液相分割比Rl等参数进行了优化,得出了它们对再沸器热负荷的影响规律。
A short-cut design method based on Fenske-Underwood-Gilliland equations for fully thermally coupled distillation column is proposed.The approach uses a shortcut method that estimates the initial specifications for the theoretical tray numbers,feed and liquid withdraw locations and the reflux ratio.By the rigorous simulations,the overhead fraction of the distributed component,as well as the split ratios for the gas and liquid phases Rv and Rl are optimized.And the influence of parameters β,Rv and Rl on the reboiler duty are also found respectively.
出处
《化工学报》
EI
CAS
CSCD
北大核心
2012年第1期177-184,共8页
CIESC Journal
基金
天津市科技支撑计划重点项目(11ZCKFGX02400)~~
关键词
能量耦合精馏塔
简捷设计
严格模拟
优化
fully thermally coupled distillation column
short-cut design method
rigorous simulation
optimization