摘要
为了揭示5MW核供热堆的运行特性,进行了一系列实验,包括正常运行的扰动,负荷改变的跟随特性和反应性引入的过渡特性。实验结果表明:当负荷改变±40%和反应性引入2mk,在没有任何外部干预下,反应堆都能安全和安稳地过渡到另一个稳定状态。
In order to reveal the operation feature of 5 MW heating reactor, a series ofexperimental study have been done, including the disturbance of normal operationcondition, load following feature and transient feature during reactivity insertion.The experimental results indicate: when the load change is ±40% and reactivityinsertion is 2 mk, the 5 MW reactor can go to another stable condition safely andsmoothly without any external interference.
出处
《原子能科学技术》
EI
CAS
CSCD
北大核心
1990年第6期37-45,共9页
Atomic Energy Science and Technology
关键词
供热堆
低温
运行特性
供热
Nuclear heating reactor
Operation feature
Load
reactivity