期刊文献+

羧基化多壁碳纳米管-Nafion修饰玻碳电极差分脉冲阳极伏安法测定痕量镉 被引量:2

Differential Pulse Anodic Stripping Voltammetric Determination of Trace Amount of Cadmium Using Carboxylated MWCNT′s-Nafion Modified GCE
在线阅读 下载PDF
导出
摘要 将羧基化多壁碳纳米管分散在Nafion溶液中并滴涂在玻碳电极表面,制备了羧基化多壁碳纳米管-Nafion修饰电极(MWCNT′s-Nafion/GCE)。应用此修饰电极测定镉时,将试液在pH 4.8乙酸-乙酸钠缓冲溶液中,于-1.1V处预还原富集350s,然后在-1.2~-0.4V范围内扫描,使镉离子从修饰电极上溶出,实现了镉离子的差分脉冲阳极伏安法测定,在-0.84V可得镉离子的氧化峰电位,镉的质量浓度在5~100μg.L-1范围内与其峰电流呈线性关系,方法的检出限(3S/N)为2.54μg.L-1。方法用于测定水样中的痕量镉,与电感耦合等离子体质谱法测定值相一致。 Carboxylated multi-wall carbon nano-tubes(MWCNT′s) was dispersed in Nafion solution,and dropped on the surface of glassy carbon electrode(GCE) to prepare MWCNT′s-Nafion modified GCE(MWCNT′s-Nafion/GCE).In the determination of Cd2+-ion,the test solution in a NaOAc-HOAc buffer solution of pH 4.8 was pre-reduced and enriched for 350 s at-1.1 V,Cd2+-ion was then stripped from the electrode by scanning in the range from-1.2 V to-0.4 V and determined by differential pulse anodic stripping voltammetry.Oxidation peak potential of Cd2+-ion was observed at-0.84 V,at where linear relationship between values of peak current of Cd2+-ion and its concentration was obtained in the range of 5-100 μg·L-1,with detection limit(3S/N) of 2.54 μg·L-1.The proposed method has been used in the determination of cadmium in water sample,giving results obtained in consistency with those obtained by ICP-MS.
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2011年第11期1343-1345,1352,共4页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
关键词 羧基化多壁碳纳米管 差分脉冲阳极伏安法 Carboxylated multi-wall carbon nano-tubes Differential pulse anodic stripping voltammetry Cadmium
  • 相关文献

参考文献8

  • 1IIJIMA S. Helical microtubules of graphitic carbon [J].Nature, 1991,354:56-58.
  • 2孙文斌,吴芳辉.多壁碳纳米管修饰玻碳电极测定乳糖酸红霉素[J].理化检验(化学分册),2008,44(1):1-4. 被引量:3
  • 3黄强,刘红英,张翠红,方宾.多璧碳管/聚中性红修饰电极的制备及对鸟嘌呤和腺嘌呤的应用研究[J].分析试验室,2009,28(9):31-34. 被引量:10
  • 4向伟,李将渊,马曾燕.多壁碳纳米管修饰金电极测定维生素B_(12)[J].化学研究与应用,2007,19(6):710-712. 被引量:10
  • 5TSAI Y C, CHEN J M, LI S C, et al. Electroanalytical thin film electrodes based on Nafion TM-multiwalled carbon nanotube composite[J]. Electrochem Commu, 2004(6):917-922.
  • 6WU Kang-bing, HU Sheng-shui, FEI Jun-jie, et al. Mercury-free simultaneous determination of cadmium and lead at a glassy carbon electrode modified with multi-wall carbon nanotubes [J]. Anal Chim Aeta, 2003,489 : 215-221.
  • 7HWANG G H, HAN W K, PARK J S, et al. Determination of trace metals by anodic stripping voltammetry using a bismuth-modified carbon nanotube electrode [J]. Talanta, 2008,76.. 301-308.
  • 8XU He, ZENG Li-ping, XING Su-jie, et al. Ultrasensitive voltammetric detection of trace lead( Ⅱ) and cad- mium( Ⅱ) using MWNT-Nafion/Bismush composite electrodes[J]. Electroanalysis, 2008, 20 (24). 2655- 2662.

二级参考文献27

共引文献19

同被引文献22

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;