摘要
目的:建立注射用复合辅酶细菌内毒素检查法。方法:按照中国药典2010年版(二部)附录ⅪE细菌内毒素检查法进行干扰试验。结果:用灵敏度λ为0.5EU/ml的鲎试剂进行实验,当注射用复合辅酶中辅酶Ⅰ的浓度为0.8μg/ml时,供试品不干扰鲎试剂与细菌内毒素的凝集反应。结论:使用鲎试剂方法检查注射用复合辅酶中细菌内毒素是可行的。
Objective:To establish a method for the detection Of bacterial endotoxins in caenzyme Complex for injection. Methods:The interfercnce test was carried out in accordance with appendix XI E,volume two,chinese pharmacopoeia 2010 edition: Results:By using tachypleus amebocyte lysates whose sensitivity was 0.5 EU/ml,tbe sample did not interfere the congregating reactivity of tachypleus amebocyte lysate with baclerial endotoxins when the concemtration of cocnzyme I was below 0.8μg/ml.Coaelusion:The method of tachypleus amebocyte lysale test is fcasibte for detecting the bacterial endotoxins in coenzyme complex for injection.
出处
《中国医药导刊》
2011年第8期1452-1453,共2页
Chinese Journal of Medicinal Guide
关键词
注射用复合辅酶
细菌内毒素
鲎试剂
Coenzyme Complex for Injection Bacterial Endotoxins
Tachypleus Amebocyte Lysate