期刊文献+

高压海底电力电缆铠装的设计和选型 被引量:14

The Design and Selection of High-voltage Submarine Power Cable Armor
在线阅读 下载PDF
导出
摘要 对高压海底电力电缆铠装的选型从结构和电气性能上进行了介绍和分析,特别是对不锈钢丝作为铠装进行了分析计算,证明考虑电缆输电损耗时,不锈钢丝不宜作为高压海底电力电缆的铠装。 The armor selection of high-voltage submarine power cables from the construction and electrical requirements are introduced and analyzed,especially for stainless steel wire armored.Analyzing and calculating show that when considering cable transmission loss,stainless steel wire should not be as a high-voltage submarine cable armor.
出处 《电线电缆》 2011年第5期19-22,共4页 Wire & Cable
关键词 海底电缆 铠装 不锈钢丝 损耗 submarine cables armor stainless steel wire loss
  • 相关文献

参考文献9

  • 1Thomas Worzyk. Submarine power cables-design, installation, re- pair, environmental aspects [ M ]. Springer-Verlag Berlin Heidel- berg, 2009.
  • 2额定电压10kV(Um=12kV)至110kV(Um=126kV)交联聚乙烯绝缘大长度交流海底电缆及附件(标准报批稿)[S].
  • 3ICEA No. S-57-401 Steel armor & associated coverings for im- pregnated paper insulated cables [ S ].
  • 4Methods to prevent mechanical damage to submarine cables[ C]// presented by Cigre Working Group 21 as Session Paper 12-21 at the 1986 Cigre Session, Paris, France.
  • 5Furugen M, et al. Completion of submarine cable lines combining low environmental impact with low cost [ J ]. Furukawa Review, 2002(21 ) :44-49.
  • 6Cigre Electra No. 171 Recommendations for mechanical tests on submarine cables[ S].
  • 7GB/T12706.2-2002额定电压1kV到35kV挤包绝缘电力电缆及附件第2部分额定电压6kV到30kV电缆[s].
  • 8IEC 60287 Electric cables-calculation of the current rating[ S].
  • 9马国栋.电线电缆载流量[M].北京:中国电力出版社,2002.