Visualization of Medpor implants using surface rendering 被引量:1

Visualization of Medpor implants using surface rendering
原文传递
导出
摘要 Background The Medpor surgical implant is one of the easiest implants in clinical practice, especially in craniomaxillofacial surgery. It is often used as a bone substitute material for the repair of skull defects and facial deformities. The Medpor implant has several advantages but its use is limited because it is radiolucent in both direct radiography and conventional computed tomography, causing serious problems with visualization. Methods In this study, a new technique for visualizing Medpor implants was evaluated in 10 patients who had undergone facial reconstruction using the material. Continuous volume scans were made using a 16-channel tomographic scanner and 3D reconstruction software was used to create surface renderings. The threshold values for surface renderings of the implant ranged from -70 HU to -20 HU, with bone as the default. Results The shape of the implants and the spatial relationship between bone and implant could both be displayed. Conclusion Surface rendering can allow successful visualization of Medpor implants in the body. Background The Medpor surgical implant is one of the easiest implants in clinical practice, especially in craniomaxillofacial surgery. It is often used as a bone substitute material for the repair of skull defects and facial deformities. The Medpor implant has several advantages but its use is limited because it is radiolucent in both direct radiography and conventional computed tomography, causing serious problems with visualization. Methods In this study, a new technique for visualizing Medpor implants was evaluated in 10 patients who had undergone facial reconstruction using the material. Continuous volume scans were made using a 16-channel tomographic scanner and 3D reconstruction software was used to create surface renderings. The threshold values for surface renderings of the implant ranged from -70 HU to -20 HU, with bone as the default. Results The shape of the implants and the spatial relationship between bone and implant could both be displayed. Conclusion Surface rendering can allow successful visualization of Medpor implants in the body.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2011年第18期2890-2893,共4页 中华医学杂志(英文版)
关键词 MEDPOR surface rendering VISUALIZATION Medpor surface rendering visualization
  • 相关文献

参考文献1

二级参考文献2

共引文献8

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部